The use of fluoroscopic devices exposes patients and operators to harmful effects of ionizing radiation in an electrophysiology (EP) lab. We sought to know if the newer fluoroscopic technology (Allura Clarity) installed in a hybrid EP helps to reduce prescribed radiation dose. We performed radiation dose analysis of 90 patients who underwent various procedures in the EP lab at a community teaching hospital after the introduction of newer fluoroscopic technology in June of 2016. Watchman device insertion, radiofrequency ablation procedures, permanent pacemaker (PPM)/implantable cardioverter defibrillator (ICD) placement and battery changes were included in the study to compare radiation exposure during different procedures performed commonly in an EP lab. In all cases of watchman device placement, radiofrequency ablation procedures, PPM/ICD placement and battery changes, there was a statistically significant difference (<0.05) in radiation dose exposure. Significant reduction in radiation exposure during various procedures performed in an EP lab was achieved with aid of newer fluoroscopic technology and better image detection technology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5595165PMC
http://dx.doi.org/10.4081/cp.2017.976DOI Listing

Publication Analysis

Top Keywords

newer fluoroscopic
12
fluoroscopic technology
12
radiation exposure
8
electrophysiology lab
8
introduction newer
8
radiation dose
8
watchman device
8
radiofrequency ablation
8
ablation procedures
8
placement battery
8

Similar Publications

Prone Transpsoas Lumbar Interbody Fusion for Degenerative Disc Disease.

JBJS Essent Surg Tech

January 2025

Department of Neurosurgery, Center for Neuroscience and Spine, Virginia Mason Medical Center, Seattle, Washington.

Background: Prone transpsoas lumbar interbody fusion (PTP) is a newer technique to treat various spinal disc pathologies. PTP is a variation of lateral lumbar interbody fusion (LLIF) that is performed with the patient prone rather than in the lateral decubitus position. This approach offers similar benefits of lateral spinal surgery, which include less blood loss, shorter hospital stay, and quicker recovery compared with traditional open spine surgery.

View Article and Find Full Text PDF

Objective: To determine the preferred ankle, knee, and elbow arthrography injection techniques for Society of Skeletal Radiology (SSR) members and whether more recently described techniques are gaining acceptance. We also sought to determine whether the concept of knowledge translation might explain differences between the preferred technique, year of fellowship graduation, and year the newer technique was described.

Materials And Methods: A 29-question survey was created in Qualtrics and submitted to current SSR members to determine if they perform knee, elbow, and ankle arthrography, and if so, the year of fellowship completion and preferred approaches.

View Article and Find Full Text PDF

Purpose: Fluoroscopically-guided neurointervention may be associated with prolonged procedure time and substantial radiation exposure to the patient and staff. This study sought to examine technological features affecting the potential radiation exposure reduction of new angiography systems, compared to older systems, for neurointerventional procedures.

Methods: Consecutive neurointerventional patients (2020-2022) were retrospectively analyzed.

View Article and Find Full Text PDF

Recurrent Valve Frame Infolding in the 34mm Self-Expanding Medtronic Evolut Pro+ Transcatheter Valve System: A Single Centre Experience.

Heart Lung Circ

December 2023

Department of Cardiology, Royal North Shore Hospital, Sydney, NSW, Australia; Department of Cardiology, North Shore Private Hospital, Sydney, NSW, Australia; Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia. Electronic address:

Background: Valve frame infolding (VFI) is a rare complication (1-3%) of transcatheter aortic valve implantation (TAVI), which primarily occurs in large sized self-expanding valves. We report the incidence of VFI in a small group of patients with highly calcified and extra-large aortic annuli, who underwent implantation of the newer generation 34mm Medtronic Evolut Pro+ (EP+) valve system.

Methods: A retrospective review was conducted on all patients presenting to a single centre experienced with TAVI in Sydney, NSW, Australia, between June and October 2022, for transfemoral TAVI using the Medtronic 34mm EP+ valve system.

View Article and Find Full Text PDF

Introduction: Occupational exposure to ionizing radiation poses health risks for veterinary interventionalists. There are limited veterinary studies evaluating radiation dose in the cardiac catheterization laboratory. The purpose of this study was to report direct radiation dose exposure to patients during common interventional cardiology procedures and compare these doses between two fluoroscopy units.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!