Due to its unique sensitivity to hydrogen protons, magnetic resonance sounding (MRS) is the only geophysical method that directly detects water and can provide nondestructive information on subsurface aquifer properties. The relationship between the surface MRS signal and the location and characteristics of aquifers using large-coil (typically 50-150 m) sensors has been discussed based on forward modelling and experiments. However, few researchers have studied underground MRS using a small-coil sensor. In this paper, a parametric study and a large-scale physical model test were conducted to shed light on the critical response characteristics of underground MRS using a small-coil sensor. The effects of the size and number of turns of the transmitter coil and receiver coil, the geomagnetic declination, the geomagnetic inclination, and the position, thickness, and water content of a water-bearing structure on the performance of the underground MRS were studied based on numerical simulations. Furthermore, we derived the kernel function and underground MRS signal curves for a water-bearing structure model based on the simulations. Finally, a large-scale physical model test on underground MRS using a small-coil sensor was performed using a physical test system for geological prediction of tunnels at Shandong University. The results show that the inversion results of the physical model test were in good agreement with the physical prototype results. Using both numerical modeling and physical model tests, this study showed that underground MRS using a small-coil sensor can be used to predict water-bearing structures in underground engineering.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5621384PMC
http://dx.doi.org/10.3390/s17092127DOI Listing

Publication Analysis

Top Keywords

small-coil sensor
20
underground small-coil
16
physical model
16
model test
12
response characteristics
8
underground
8
study underground
8
magnetic resonance
8
resonance sounding
8
large-scale physical
8

Similar Publications

Contactless Electrocatheter Tracing within Human Body via Magnetic Sensing: A Feasibility Study.

Sensors (Basel)

May 2022

Department of Electrical Engineering and Information Technologies, University of Naples Federico II, Via Claudio, 21, 80125 Napoli, Italy.

During surgical procedures, real-time estimation of the current position of a metal lead within the patient's body is obtained by radiographic imaging. The inherent opacity of metal objects allows their visualization using X-ray fluoroscopic devices. Although fluoroscopy uses reduced radiation intensities, the overall X-ray dose delivered during prolonged exposure times poses risks to the safety of patients and physicians.

View Article and Find Full Text PDF

Due to its unique sensitivity to hydrogen protons, magnetic resonance sounding (MRS) is the only geophysical method that directly detects water and can provide nondestructive information on subsurface aquifer properties. The relationship between the surface MRS signal and the location and characteristics of aquifers using large-coil (typically 50-150 m) sensors has been discussed based on forward modelling and experiments. However, few researchers have studied underground MRS using a small-coil sensor.

View Article and Find Full Text PDF

Characterizing the human head as a propagation medium is vital for the design of both on-body and implanted antennas and radio-frequency sensors. The following problem has been addressed: find the best radio-frequency path through the brain for a given receiver position-on the top of the sinus cavity. Two parameters, transmitter position and radiating frequency, should be optimized simultaneously such that 1) the propagation path through the brain is the longest; and 2) the received power is maximized.

View Article and Find Full Text PDF

A new instrumented hip joint prosthesis was developed which allows the in vivo measurement of the complete contact loads in the joint, i.e. 3 force and 3 moment components.

View Article and Find Full Text PDF

Sensitivity of a single coil electromagnetic sensor for non-contact monitoring of breathing.

Annu Int Conf IEEE Eng Med Biol Soc

May 2009

Department of Systems and Computer Engineering, Carleton University, Ottawa, Canada.

We design and analyse a flexible non-contact electromagnetic sensor for monitoring breathing. This paper presents the sensor design and the theoretical model for the expected sensitivity from which we optimize design components. The primary application of this device is in non-invasive sleep monitoring and it has the potential to be useful for detection of both adult and infant apnea.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!