Objective: Blood pressure (BP) measurement is recommended on bare arms, but undressing the arms for BP measurements is often difficult for frail elderly individuals. We aimed to assess the accuracy of BP measurements over arms with thin and thick clothing among the frail elderly.
Participants And Methods: This is a cross-sectional study. Individuals aged 65 years or older were recruited from three long-term care facilities in Japan between April and May 2016. The main outcome measures were BP measurements (a) on a bare arm, (b) over a thin shirt, (c) over a thin shirt and a cardigan, and (d) over the sleeve of a thin shirt and a cardigan rolled up to the elbow. BP was compared across measurements using the paired t-test and multiple analysis of variance adjusting for sex and treatments for hypertension.
Results: Of 147 participants, 23.8% were men. The mean age of the participants was 87.2 years (SD: 7.8). The mean (SD) BP on a bare arm, over a shirt, over a shirt and a cardigan, and over a rolled-up sleeve were 128.8 (20.0)/69.3 (13.2), 131.0 (22.2)/73.9 (15.2), 136.9 (22.2)/78.9 (15.8), and 136.4 (26.0)/80.7 (15.9) mmHg, respectively. BP measurements over clothed arms were significantly higher than bare arm measurements. BP differences were significant when measured over a cardigan after adjusting for sex and treatments for hypertension.
Conclusion: In the elderly, clothing has a significant effect on BP measurements. The arms should be undressed as much as possible for BP measurements in the elderly.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MBP.0000000000000294 | DOI Listing |
Cureus
November 2024
Division of Interventional Radiology, Columbia University Irving Medical Center, New York, USA.
Aim This study aims to evaluate the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) check and revision procedures performed in a freestanding interventional radiology (IR) outpatient facility. Methodology A total of 40 patients (male 31:female 9, median age 60 years old) underwent a TIPS check and/or revision at a freestanding IR outpatient facility between 2009 and 2017. Procedures were performed using a mobile C-arm unit under intravenous (IV) moderate sedation, with the patient discharged home on the same day.
View Article and Find Full Text PDFJ Cardiol Cases
December 2024
Department of Cardiology, Japanese Red Cross Ashikaga Hospital, Ashikaga, Japan.
Unlabelled: Data about the long-term safety and efficacy of stent implantation for central venous stenosis in patients on dialysis are limited. We report the case of a 66-year-old man on hemodialysis for end-stage renal disease who presented with stasis dermatitis around an arteriovenous shunt with ulceration of the left forearm. Computed tomography angiography showed a tight stenosis of the proximal left subclavian vein and the development of collateral blood vessels around the stenosis.
View Article and Find Full Text PDFJ Hum Hypertens
December 2024
School of Cardiovascular and Metabolic Health, University of Glasgow, Glasgow, UK.
Blood pressure (BP) measurement is a common procedure conducted in various disciplines and is widely available on clinical reports. The diagnosis and management of hypertension require reliable measurement of BP in outpatient clinics. Published studies suggest the standardised method for BP measurement is difficult to apply in routine clinical practice.
View Article and Find Full Text PDFHypertension
January 2025
Menzies Institute for Medical Research, College of Health and Medicine, University of Tasmania, Hobart, Australia (E.C., D.S.P., S.C., J.S., C.B., N.C.).
Background: Patient education is needed to perform home blood pressure measurement (HBPM) according to blood pressure (BP) guidelines. It is not known how BP is measured at home and what education is provided, which was the aim of the study.
Methods: Mixed-methods study among Australian adults who perform HBPM (June to December 2023).
Ophthalmol Sci
May 2024
Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia.
Purpose: To assess the feasibility of a second-generation (44-channel) suprachoroidal retinal prosthesis for provision of functional vision in recipients with end-stage retinitis pigmentosa (RP) over 2.7 years.
Design: Prospective, single-arm, unmasked interventional clinical trial.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!