Purpose: The purpose of this study is to assess the dose of ionizing radiation caused by repeated CT scans performed to investigate non-traumatic acute abdominal conditions in young adults.

Methods: Over 26 months, we collected a cohort of patients aged 18 to 45 years who were subject to at least one urgent contrast-enhanced abdomen/pelvis CT. Patients affected with urolithiasis, HIV infection, tumors, and vascular and chronic inflammatory bowel diseases were excluded. All abdomen/pelvis CT scans carried out at our institution for over 6 years were retrospectively tallied, and the effective doses (EDs) were computed by multiplying the total dose-length product by the appropriate anatomic conversion factor. Examples of age- and gender-adjusted lifetime attributable cancer risks were estimated using the online calculator Radiation Risk Assessment Tool.

Results: Sixty-one patients (average age 34.2 years) received multiple CT scans (average 2.7 scans per patient). ED largely varied among single- and multi-phase acquisitions. Cumulative ED ranged from 14.1 mSv to a maximum of 436.6 mSv (average 70.1 mSv per person). Twenty-five patients (40.9%) received more than 50 mSv, 84% of them within year; 12 (19.7%) and 4 (6.6%) patients received more than 100 and 200 mSv, respectively.

Conclusion: Young adults are subject to repetitive CT imaging to monitor urogenital, intestinal, hepatobiliary, and pancreatic disorders during non-operative management to detect and follow up abdominal emergencies requiring surgical intervention and to assess post-surgical complications. In this population, the risk of accruing high cumulative radiation exposure should be considered.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10140-017-1554-yDOI Listing

Publication Analysis

Top Keywords

repeated scans
8
young adults
8
acute abdominal
8
scans
5
patients
5
radiation
4
radiation overexposure
4
overexposure repeated
4
scans young
4
adults acute
4

Similar Publications

The maintenance of an appropriate ratio of body fat to muscle mass is essential for the preservation of health and performance, as excessive body fat is associated with an increased risk of various diseases. Accurate body composition assessment requires precise segmentation of structures. In this study we developed a novel automatic machine learning approach for volumetric segmentation and quantitative assessment of MRI volumes and investigated the efficacy of using a machine learning algorithm to assess muscle, subcutaneous adipose tissue (SAT), and bone volume of the thigh before and after a strength training.

View Article and Find Full Text PDF

Background Endoscopic dilatation is the cornerstone therapy for esophageal strictures. The primary indication for dilatation is to provide immediate and durable symptomatic relief from dysphagia. Following esophageal dilatation, the two most common major consequences are bleeding and perforation, both of which are quite rare.

View Article and Find Full Text PDF

Investigate the impact of antimicrobial photodynamic therapy (aPDT) using different photosensitizers (PSs) such as indocyanine green (IG), curcumin (CC), and methylene blue (MB), with or without intracanal application of calcium hydroxide (CH), on the push-out bond strength of glass-fiber posts (GFPs) to intraradicular dentin, the chemical composition of the root substrate, and the sealing of the adhesive interface across different thirds of intraradicular dentin. A total of 112 bovine teeth underwent biomechanical preparation and were divided into eight experimental groups (n = 14 each): Negative control with deionized water; positive control with deionized water + CH; IG group with indocyanine green and infrared laser; IG + CH group; CC group with curcumin and blue LED; CC + CH group; MB group with methylene blue and red laser; and MB + CH group. The push-out bond strength was measured using a universal testing machine (n = 8), and scanning electron microscopy characterized the fracture patterns.

View Article and Find Full Text PDF

Osseointegration for transfemoral amputees: Influence of femur length and implant sizing on bone-implant contact and alignment.

Injury

January 2025

Department of Orthopedic Surgery, McGovern Medical School, UTHealth Science Center at Houston, 5420 West Loop S. Suite 1300, Bellaire, TX, 77401, USA. Electronic address:

Introduction: Clinical data on osseointegration (OI) for limb replacement indicates a concerning increase in mechanical complications after five years post-implantation. Since adequate bone-implant contact and proper implant alignment are critical factors for successful osseointegration, it is essential to identify the factors influencing these outcomes. This study aimed to assess the effects of residual femur length and implant sizing on bone-implant contact and implant alignment.

View Article and Find Full Text PDF

Purpose: To investigate image quality and agreement of derived cardiac function parameters in a novel joint image reconstruction and segmentation approach based on disentangled representation learning, enabling real-time cardiac cine imaging during free-breathing.

Methods: A multi-tasking neural network architecture, incorporating disentangled representation learning, was trained using simulated examinations based on data from a public repository along with MR scans specifically acquired for model development. An exploratory feasibility study evaluated the method on undersampled real-time acquisitions using an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!