T wave oversensing (TWOS) is a major drawback of implantable cardioverter defibrillator (ICD) and data on predictors of TWOS in ICD is limited. We aimed to calculate a novel index of T wave safety margin (TWSM) and assess its potential for evaluating TWOS during the procedure of ICD implantation. Thirty-two consecutive patients with ICD implantation were enrolled. During each procedure of ICD implantation, different ICD generators were connected to implanted sensing lead through active-fixation leads and bridging cables. R and T wave amplitudes were measured on ICD printouts according to the gain. The ICDs were programed to the most sensitive settings to reveal possible TWOS. A novel index TWSM was calculated according to the corresponding sensing algorithm of ICD. There was discrepancy of R wave amplitudes measured by different ICDs ( < 0.01). In Fortify and Teligen ICDs, T wave amplitudes showed no difference ( > 0.05) and TWSMs were sufficiently high (post sensing: 13.0 ± 7.6 and 28.3 ± 16.5, respectively, post pacing: 5.0 ± 2.2 and 4.6 ± 0.9, respectively). In nine patients with 10 TWOS episodes detected during the procedure of ICD implantation, generators with the highest TWSM were chosen. Only one TWOS episode during pacing was recorded during the 25 ± 7 mo follow-up period. We first propose the index of TWSM during ICD implantation as a potentially efficient predictor for TWOS. Evaluation of TWSM might help to reduce TWOS episodes in patients with high risk of TWOS. Prospective studies are warranted to validate this index and its potential to reduce TWOS episodes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5585188PMC
http://dx.doi.org/10.3389/fphys.2017.00659DOI Listing

Publication Analysis

Top Keywords

icd implantation
24
procedure icd
12
wave amplitudes
12
twos episodes
12
icd
11
twos
10
wave safety
8
safety margin
8
wave oversensing
8
amplitudes measured
8

Similar Publications

Background: Charcot-Marie-Tooth is the most common inherited neuromuscular disorder. Rarely, it can be associated with heart failure and various arrhythmic disturbances. This case illustrates the challenges of making decisions to prevent sudden cardiac death in a patient with Charcot-Marie-Tooth disease.

View Article and Find Full Text PDF

Background: Breast implants interfere with myocardial perfusion imaging (SPECT) and echocardiographic windows leading to increased false positive results. To validate this concept, we hypothesized that patients with breast implants should have higher positive cardiac testing and coronary angiogram with lower percutaneous coronary intervention (PCI) rates compared to women without a breast implant.

Methods: Using ICD 10 codes for breast implants, abnormal results of cardiac functional study, coronary angiogram, and percutaneous coronary interventions, we evaluated any association between these parameters in adult women with breast implants utilizing the National Inpatient Sample (NIS) database.

View Article and Find Full Text PDF

BAY 2413555 is a novel selective and reversible positive allosteric modulator of the type 2 muscarinic acetylcholine (M2) receptor, aimed at enhancing parasympathetic signaling and restoring cardiac autonomic balance for the treatment of heart failure (HF). This study tested the safety, tolerability and pharmacokinetics of this novel therapeutic option. REMOTE-HF was a multicenter, double-blind, randomized, placebo-controlled, phase Ib dose-titration study with two active arms.

View Article and Find Full Text PDF

Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a rare inherited arrhythmia disorder characterized by ventricular arrhythmia triggered by adrenergic stimulation.

Case Presentation: A 9-year-old boy presented with convulsions following physical exertion. Bidirectional ventricular tachycardia (VT) during a treadmill test led to the diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT).

View Article and Find Full Text PDF

Medical and advanced heart failure therapies in Türkiye.

Turk J Med Sci

December 2024

Deputy Health Minister, Ministry of Health, Ankara, Turkiye.

Background/aim: Effective management of heart failure involves evidence-based use of multiple medications and their combinations. Furthermore, dosage escalation of the recommended medications is advised. In cases of advanced heart failure, long-term mechanical assistance devices or heart transplantation surgery may be necessary.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!