Determination of Tc in fresh water using TRU resin by ICP-MS.

Anal Chim Acta

Canadian Nuclear Laboratories (CNL), Radiological Protection Research and Instrumentation Branch, Chalk River, ON, K0J 1J0, Canada.

Published: October 2017

Technetium-99 (Tc) determination at trace level by inductively coupled plasma mass spectrometry (ICP-MS) is challenging because there is no readily available appropriate Tc isotopic tracer. A new method using Re as a recovery tracer to determine Tc in fresh water samples, which does not require any evaporation step, was developed. Tc(VII) and Re(VII) were pre-concentrated on a small anion exchange resin (AER) cartridge from one litre of water sample. They were then efficiently eluted from the AER using a potassium permanganate (KMnO) solution. After the reduction of KMnO in 2 M sulfuric acid solution, the sample was passed through a small TRU resin cartridge. Tc(VII) and Re(VII) retained on the TRU resin were eluted using near boiling water, which can be directly used for the ICP-MS measurement. The results for method optimisation, validation and application were reported.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2017.08.013DOI Listing

Publication Analysis

Top Keywords

tru resin
12
fresh water
8
tcvii revii
8
determination fresh
4
water
4
water tru
4
resin
4
resin icp-ms
4
icp-ms technetium-99
4
technetium-99 determination
4

Similar Publications

This study presents a new procedure for high-precision Sm isotope analysis by thermal ionisation mass spectrometry (TIMS) for geological samples. A four-step chemical separation scheme results in sharp separation of Sm and Nd from the same sample aliquot. The first step utilises anion exchange resin to remove Fe from the sample solution.

View Article and Find Full Text PDF

Environmental monitoring of alpha-emitting radionuclides is crucial for assessing the long-term impacts of nuclear activities and understanding ecosystem dynamics. Thus, long-term marine environmental monitoring needs a precise analytical method for determining isotopes in sediment and soil samples. Because Am is the first decay product of Pu, its activity in the environment will grow during the next 50 years.

View Article and Find Full Text PDF

Proof-of-concept studies of novel protocols for producing highly pure V from a Cr/V generator.

Appl Radiat Isot

September 2023

Department of Chemistry, Michigan State University, East Lansing, MI, 48824, USA; Facility for Rare Isotope Beams, Michigan State University, East Lansing, MI, 48824, USA. Electronic address:

The quest to improve the quality of nuclear data, such as half-lives, transition yields, and reaction cross-sections, is a shared endeavor among various areas of nuclear science. V is a vanadium isotope for which experimental data on neutron reaction cross-sections is needed. However, traditional isotope production techniques cannot produce V with high enough isotopic purity for some of these measurements.

View Article and Find Full Text PDF

This report presents a new methodology to isolate and measure Po, as well as uranium and thorium isotopes. This new methodology reduces the standard time of operation, the minimum amount of chemical reagents and the quantity of resin used in comparison with other standard and well-established procedures for alpha spectrometry. Thus, the amount of chemicals reagent was lower than the amount used in other standard radiochemical processes: only 6 mL of 1 M HCl was used for the thorium elution, and 2 mL of HO and 1 mL of Ammonium Oxalate (0.

View Article and Find Full Text PDF

Fundamental distribution coefficient data and separations using eichrom extraction chromatographic resins.

J Chromatogr A

June 2020

Idaho National Laboratory, 1765 N Yellowstone, PO Box 1625, Hwy Idaho Falls, ID 83415-2805, United States. Electronic address:

Distribution coefficient (Kd) data provides the analyst with a powerful set of tools for designing elemental chemical separations. While considerable Kd data exists in the literature for traditional anion and cation exchange resins, a comprehensive Kd study for the majority of the periodic table has not been published to date for several newer Eichrom extraction chromatographic resins. Kd values for the sorption of 41 different of elements on TEVA, TRU, UTEVA, and Diphonix resin were determined in this work.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!