Infection Staging and Incidence Surveillance Applications of High Dynamic Range Diagnostic Immuno-Assay Platforms.

J Acquir Immune Defic Syndr

*South African Centre for Epidemiological Modelling and Analysis (SACEMA), Stellenbosch University, Stellenbosch, South Africa; †National Infection Service, Public Health England, London, United Kingdom; ‡Blood Systems Research Institute, San Francisco, CA; §School of Medicine, University of California, San Francisco, San Francisco, CA; ‖Division of Infectious Diseases, Department of Medicine, University of California, San Diego, San Diego, CA; ¶Department of Medical Affairs, International AIDS Vaccine Initiative (IAVI), New York City, NY; and #Division of Clinical Immunology and Allergy, School of Medicine, University of São Paulo, São Paulo, Brazil.

Published: December 2017

Background: Custom HIV staging assays, including the Sedia HIV-1 Limiting Antigen (LAg) Avidity EIA and avidity modifications of the Ortho VITROS anti-HIV-1+2 and Abbott ARCHITECT HIV Ag/Ab Combo assays, are used to identify "recent" infections in clinical settings and for cross-sectional HIV incidence estimation. However, the high dynamic range of chemiluminescent platforms allows differentiating recent and long-standing infection on signal intensity, and this raises the prospect of using unmodified diagnostic assays for infection timing and surveillance applications.

Methods: We tested a panel of 2500 well-characterized specimens with estimable duration of HIV infection with the 3 assays and the unmodified ARCHITECT. Regression models were used to estimate mean durations of recent infection (MDRIs), context-specific false-recent rates (FRRs) and correlation between diagnostic signal intensity and LAg measurements. Hypothetical epidemiological scenarios were constructed to evaluate utility in surveillance applications.

Results: Over a range of MDRIs (reflecting recency discrimination thresholds), a diluted ARCHITECT-based RITA produced lower FRRs than the VITROS platform (FRR ≈ 0.5% and 1.5%, respectively at MDRI ≈ 200 days), and the unmodified diagnostic ARCHITECT produces incidence estimates with comparable precision to LAg (relative SE ≈ 17.5% and 15%, respectively at MDRI ≈ 200 days). ARCHITECT S/CO measurements were highly correlated with LAg optical density measurements (r = 0.80), and values below 200 are strongly predictive of LAg recency and duration of infection less than 1 year.

Conclusions: Low quantitative measurements from the unmodified ARCHITECT obviate the need for additional recency testing, and its use is feasible in clinical staging and incidence surveillance applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5680100PMC
http://dx.doi.org/10.1097/QAI.0000000000001537DOI Listing

Publication Analysis

Top Keywords

staging incidence
8
incidence surveillance
8
surveillance applications
8
high dynamic
8
dynamic range
8
signal intensity
8
unmodified diagnostic
8
unmodified architect
8
15% mdri
8
mdri ≈
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!