The data presented in this article are related to the research article entitled "Optical coherence tomography guidance for the management of angiographically intermediate left main bifurcation lesions: early clinical experience" [1]. In this article we reports details about our clinical experience with frequency domain-optical coherence tomography (FD-OCT) guidance for the management of patients with left main (LM) bifurcation lesions of intermediate angiographic severity. LM patients were assessed by FD-OCT and, on the bases of the findings, managed by myocardial revascularization or conservative treatment (revascularization deferral). The observed outcomes support the feasibility of FD-OCT guidance for LM bifurcated lesions and call for further clinical evaluations in appropriately designed prospective studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5587878PMC
http://dx.doi.org/10.1016/j.dib.2017.08.015DOI Listing

Publication Analysis

Top Keywords

coherence tomography
12
guidance management
12
left main
12
main bifurcation
12
bifurcation lesions
12
tomography guidance
8
management angiographically
8
angiographically intermediate
8
intermediate left
8
fd-oct guidance
8

Similar Publications

Bacillary layer detachment: Updates on its clinical and prognostic significance in retinal disease.

Surv Ophthalmol

January 2025

Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072 Pieve Emanuele-Milan, Italy; Department of Ophthalmology, Eye Unit Humanitas Gavazzeni-Castelli, via Mazzini 11, Bergamo, Italy.

Bacillary layer detachment (BALAD) refers to the distinctive splitting at the level of the photoreceptor inner segment myoid and accumulation of intraretinal fluid, as seen on optical coherence tomography (OCT).BALAD is an increasingly recognized OCT biomarker of numerous heterogeneous chorioretinal diseases, including posterior uveitis, age-related macular degeneration and macular neovascularization, neoplastic and paraneoplastic retinal disorders, rhegmatogenous retinal detachment, blunt ocular trauma, and miscellaneous conditions. The recognition of BALAD is clinically relevant because, based on the specific etiology, BALAD may require simple observation, ocular or systemic medical treatment, or even surgical intervention, with subsequent different prognosis.

View Article and Find Full Text PDF

Background: An idiopathic macular hole (IMH) is a foveal opening in the neurosensory retina caused by perifoveal vitreomacular traction and detachment. IMH prevalence varies considerably across populations, highlighting a need for further investigation, especially in underrepresented groups such as Hispanics.

Methods: This retrospective, descriptive, cross-sectional study analyzed IMH prevalence in a Hispanic population over four years.

View Article and Find Full Text PDF

The choroid, a critical vascular layer beneath the retina, is essential for maintaining retinal function and monitoring chorioretinal disorders. Existing imaging methods, such as indocyanine green angiography (ICGA) and optical coherence tomography (OCT), face significant limitations, including contrast agent requirements, restricted field of view (FOV), and high costs, limiting accessibility. To address these challenges, we developed a nonmydriatic, contrast agent-free fundus camera utilizing transcranial near-infrared (NIR) illumination.

View Article and Find Full Text PDF

Conventional scanned optical coherence tomography (OCT) suffers from the frame rate/resolution tradeoff, whereby increasing image resolution leads to decreases in the maximum achievable frame rate. To overcome this limitation, we propose two variants of machine learning (ML)-based adaptive scanning approaches: one using a ConvLSTM-based sequential prediction model and another leveraging a temporal attention unit (TAU)-based parallel prediction model for scene dynamics prediction. These models are integrated with a kinodynamic path planner based on the clustered traveling salesperson problem to create two versions of ML-based adaptive scanning pipelines.

View Article and Find Full Text PDF

Monte Carlo-based realistic simulation of optical coherence tomography angiography.

Biomed Opt Express

January 2025

Department of Electronic Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.

Optical coherence tomography angiography (OCTA) offers unparalleled capabilities for non-invasive detection of vessels. However, the lack of accurate models for light-tissue interaction in OCTA jeopardizes the development of the techniques to further extract quantitative information from the measurements. In this manuscript, we propose a Monte Carlo (MC)-based simulation method to precisely describe the signal formation of OCTA based on the fundamental theory of light-tissue interactions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!