External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICC<0.70). Improved CoP measures were present on the second visit indicating a potential learning effect. Non-perturbation conditions generally produced more reliable CoP measures than perturbation conditions during double leg standing, but not single leg standing. Therefore, changes to balance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.gaitpost.2017.09.007 | DOI Listing |
Q J Nucl Med Mol Imaging
January 2025
Section of Nuclear Medicine and Diagnostic Imaging, International Atomic Energy Agency, Vienna, Austria.
Background: One can assess cortical defects on the early images of [99mTc]Tc-MAG3 renography. We aimed to assess interobserver and intraobserver reproducibility for detecting renal cortical defects using [99mTc]Tc-MAG3 for adults and children; identify causes for poor inter- and intraobserver reproducibility and to assess the effect of the kidney to background ratio (KTBR) on reproducibility.
Methods: One hundred adult and 200 pediatric renograms were included.
JAMA Neurol
January 2025
Department of Neural and Pain Sciences, University of Maryland School of Dentistry, Baltimore.
Importance: Biomarkers would greatly assist decision-making in the diagnosis, prevention, and treatment of chronic pain.
Objective: To undertake analytical validation of a sensorimotor cortical biomarker signature for pain consisting of 2 measures: sensorimotor peak alpha frequency (PAF) and corticomotor excitability (CME).
Design, Setting, And Participants: This cohort study at a single center (Neuroscience Research Australia) recruited participants from November 2020 to October 2022 through notices placed online and at universities across Australia.
Anal Chem
January 2025
State Key Laboratory of Cellular Stress Biology, Institute of Artificial Intelligence, School of Life Sciences, Faculty of Medicine and Life Sciences, National Institute for Data Science in Health and Medicine, XMU-HBN skin biomedical research center, Xiamen University, Xiamen, Fujian 361102, China.
In metabolomic analysis based on liquid chromatography coupled with mass spectrometry, detecting and quantifying intricate objects is a massive job. Current peak picking methods still cause high rates of incorrectly picked peaks to influence the reliability and reproducibility of results. To address these challenges, we developed QuanFormer, a deep learning method based on object detection designed to accurately quantify peak signals.
View Article and Find Full Text PDFInt J Rheum Dis
January 2025
School of Nursing, Peking University, Beijing, People's Republic of China.
Background: In Chinese intervention studies, the lack of specific self-care scales based on the functional characteristics of Rheumatoid arthritis (RA) patients has caused patients and researchers to spend a great deal of time completing multiple related scales during the research work. Therefore, the arthritis Self-Care Behaviors Scale (SCBS) was developed to evaluate the self-care behavior of patients with arthritis.
Objective: The objectives of this study were to translate the SCBS into Chinese and test its psychometric properties in Chinese patients with RA.
Behav Neurol
January 2025
Department of Pediatric Psychology, College of Medicine, Balcalı Hospital, Çukurova University, Adana, Turkey.
According to the International League Against Epilepsy (ILAE) 2015 classification, status epilepticus (SE) is a seizure that lasts longer than 5 min or a frequency of more than one seizure within 5 min, without returning to a normal level of consciousness between episodes. In this study, we aimed to evaluate the prognostic factors of SE and compare our patients with those of patients treated internationally with the modified status epilepticus severity score (mSTESS) to determine the reliability of this scoring system. The medical records of patients aged 1 month-17 years with SE who were treated at Çukurova University-Balcalı Training and Research Hospital between September 2018 and September 2021 and who were followed in the intensive care unit were included in the study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!