Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

Curr Eye Res

a Department of Ophthalmology, Medical Faculty , Yüzüncü Yil University, Van , Turkey.

Published: November 2017

Purpose: The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX).

Methods: This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded.

Results: Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81).

Conclusions: With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02713683.2017.1338349DOI Listing

Publication Analysis

Top Keywords

lens capsule
24
pex group
24
control group
20
anterior lens
16
group
11
capsule iris
8
pex
8
pupillary diameter
8
iris thickness
8
thicker pex
8

Similar Publications

Background: Human anterior lens capsules (ALCs) have great potential in the treatment of multiple eye diseases, including corneal ulcers, glaucoma, age-related macular degeneration and macular holes. ALCs are also regarded as promising scaffolds for various ocular cells. Here, we investigated different decellularization methods for removing lens epithelial cells (LECs) that adhered to ALCs.

View Article and Find Full Text PDF

Rationale: The double-layer sign of the anterior lens capsule during continuous curvilinear capsulorrhexis (CCC) in cataract surgery is a rare phenomenon. This case report highlights the occurrence of this sign and provides a practical technique for managing it.

Patient Concerns: A 55-year-old Chinese woman presented with blurred vision in her left eye.

View Article and Find Full Text PDF

Purpose: To evaluate demographic profile, risk factors and outcomes following intraocular lens (IOL) exchange surgery for late decentration of IOLs in the dead bag syndrome DESIGN: Prospective, interventional case series PARTICIPANTS: 46 eyes (43 patients) with late decentration/dislocation of IOLs and spontaneous posterior capsule rupture in a clear and relatively intact capsular bag. None of the eyes had significant zonular weakness.

Methods: Study conducted at Raghudeep Eye Hospital, India.

View Article and Find Full Text PDF

Purpose: Severely myopic eyes have been associated with high posterior capsule opacification (PCO) incidence. Although it has been reported that myopic eyes have weaker or more delayed capsule adhesion than emmetropic eyes, it is unclear whether/how dioptric power and posterior curvature of IOLs affect IOLs' affinity for the posterior lens capsule (PLC) and their PCO potential.

Methods: To investigate this, acrylic foldable IOLs with increasing dioptric power of 6.

View Article and Find Full Text PDF

Introduction: In the era of functional intraocular lens (IOL) implantation, it is crucial to investigate the influence of different capsulorhexis sizes (including the diameter of the capsulorhexis, area of the anterior capsule opening, anterior capsule coverage, centration and circularity of the capsulorhexis) on the postoperative outcomes (eg, visual acuity, capsule shrinkage, IOL stability and intraocular pressure) in patients undergoing cataract surgery. This is particularly important in patients with high myopia or diabetes mellitus. The proposed protocol aims to enhance the transparency of our research and offer references for future studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!