Gated thoracic magnetic resonance angiography at 3T: noncontrast versus blood pool contrast.

Int J Cardiovasc Imaging

Department of Radiology and Biomedical Imaging, University of California San Francisco, 505 Parnassus Avenue, San Francisco, CA, 94143, USA.

Published: March 2018

Both noncontrast and contrast-enhanced approaches to gated thoracic magnetic resonance angiography (MRA) for aortic root evaluation have been reported at 3T. We compare qualitative and quantitative image quality measures for the two approaches, and assess the reproducibility of standard aortic measurements. Respiratory and cardiac gated MRA of the chest was performed at 3T in 45 patients: 23 after administration of iron-based blood pool contrast, and 22 without contrast. Image quality was assessed with a 5-point Likert scale, vessel lumen-to-muscle contrast ratios, and vessel wall sharpness. Two reviewers measured the ascending aorta diameter and valve annulus area. Interrater agreement was assessed using Bland-Altman plots and coefficient of variation (CV). Qualitative image quality was better with blood pool contrast in all principal vessels of the chest (mean Likert of 4.20 ± 0.79 vs. 2.60 ± 0.77, p < 0.001). Quantitative assessment was also improved with higher contrast ratios in all vessels (5.26 ± 3.3 vs. 1.90 ± 0.53, p < 0.001), and greater sharpness of the aortic annulus and ascending aorta (0.70 ± 0.16 vs. 0.56 ± 0.14 mm, p < 0.001, and 0.87 ± 0.16 vs. 0.62 ± 0.16 mm, p = 0.008, respectively). Reproducibility of measurement was marginally better for the ascending aorta diameter (CV of 2.80 vs. 3.23%), but substantially increased for the aortic valve annulus area with blood pool contrast (CV of 4.93 vs. 7.32%). The use of a blood pool contrast agent for gated thoracic MRA improves image quality compared to a noncontrast technique, and provides more reproducible measurements of the aortic valve annulus area.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5826886PMC
http://dx.doi.org/10.1007/s10554-017-1242-8DOI Listing

Publication Analysis

Top Keywords

blood pool
12
pool contrast
12
image quality
12
gated thoracic
8
thoracic magnetic
8
magnetic resonance
8
resonance angiography
8
contrast
5
angiography noncontrast
4
noncontrast versus
4

Similar Publications

Preclinical and First-In-Human Imaging of Novel [F]F-FAPI-FUSCC-07 Tracer: Comparative Prospective Study with [F]F-FAPI-42 and [F]F-FAPI-74.

Mol Pharm

January 2025

Department of Nuclear Medicine, Fudan University Shanghai Cancer Center; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China.

This study aimed to develop and evaluate a novel fibroblast activation protein (FAP)-specific tracer, fluorine-18-labeled fibroblast activation protein inhibitor-FUSCC-07 ([F]F-FAPI-FUSCC-07), for use in both preclinical and clinical settings. Preclinical evaluations were conducted to assess the stability and partition coefficient of [F]F-FAPI-FUSCC-07. Experiments involving human glioma U87MG cells demonstrated its cellular uptake and inhibitory properties.

View Article and Find Full Text PDF

Introduction: Previous studies highlighted the association between the triglyceride-glucose (TyG) index and cardiovascular events in patients with diabetes. However, whether diabetes affects TyG-cardiovascular diseases (CVD) is still unclear. This study aimed to evaluate the association between the TyG index and CVD risk, stratified by diabetes status, as well as the potential modifying effect of diabetic status.

View Article and Find Full Text PDF

Human Immunodeficiency Virus (HIV) proviral reservoirs are cells that harbor integrated HIV proviral DNA within their nuclear genomes. These cells form a heterogeneous group, represented by peripheral blood mononuclear cells (PBMCs), tissue-resident lymphoid and monocytic cells, and glial cells of the central nervous system. The importance of studying the properties of proviral reservoirs is connected with the inaccessibility of integrated HIV proviral DNA for modern anti-retroviral therapies (ARTs) that block virus reproduction.

View Article and Find Full Text PDF

Thymoglobulin is used to prevent allograft rejection and is being explored at low doses as intervention immunotherapy in type 1 diabetes. Thymoglobulin consists of a diverse pool of rabbit antibodies directed against many different targets on human thymocytes that can also be expressed by other leukocytes. Since Thymoglobulin is generated by injecting rabbits with human thymocytes, this conceivably leads to differences between Thymoglobulin batches.

View Article and Find Full Text PDF

Mendelian disorders of the epigenetic machinery (MDEMs) include a large number of conditions caused by defective activity of a member of the epigenetic machinery. MDEMs are characterized by multiple congenital abnormalities, intellectual disability and abnormal growth. that can be variably up- or down-regulated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!