The current regulatory guidelines recommend the use of QT interval to assess the risk of arrhythmogenic potential of new chemical entities. Recently, the electromechanical window (EMW), the difference in duration between electrical and mechanical systole, has been proposed as markers for drug-induced torsades de pointes (TdP); however, data of EMW in short QT model are not available. This study aimed to characterize the EMW as a marker for drug-induced ventricular arrhythmias in anesthetized rabbit model of long QT syndrome type 2 (LQT2) and short QT syndrome (SQTS) infused with reference compounds known to lengthen or shorten QT intervals. After rabbits were anesthetized with isoflurane, body surface electrocardiograms and left ventricular pressure were recorded. The LQT2 was produced by intravenous infusion with dofetilide (n = 6), quinidine (n = 6) and sotalol (n = 6) whereas the SQTS was induced by intravenous escalating concentrations of nicorandil (n = 7), pinacidil (n = 5) and cromakalim (n = 5). The EMW in anesthetized rabbits ranged from 1.3 to 53.3 msec. All three drugs known to lengthen QT intervals prolonged QT and QTcF interval while the EMW was markedly decreased to negative values. Pinacidil significantly produced QT and QTcF shortening and significantly abbreviated the EMW (p < 0.05). This study demonstrated that the EMW is associated with QT intervals (p < 0.001). It is negative in the presence of QT-prolonging drugs while it is more positive in the presence of QT-shortening drugs. The results suggest that the EMW in anesthetized rabbits can be used in drug safety evaluation in addition to the QT interval.

Download full-text PDF

Source
http://dx.doi.org/10.2131/jts.42.579DOI Listing

Publication Analysis

Top Keywords

electromechanical window
8
anesthetized rabbit
8
emw
8
emw anesthetized
8
anesthetized rabbits
8
anesthetized
5
characteristics electromechanical
4
window anesthetized
4
rabbit models
4
models short
4

Similar Publications

Rheology describes the flow of fluids from food and plastics, to coatings, adhesives, and 3D printing inks, and is commonly denoted by viscosity alone as a simplification. While viscometers adequately probe Newtonian (constant) viscosity, most fluids have complex viscosity, requiring tests over multiple shear rates, and transient measurements. As a result, rheometers are typically large, expensive, and require additional infrastructure (e.

View Article and Find Full Text PDF

Electromyography (EMG) stands out as an accessible and inexpensive method for identifying muscle contractions on the surface and within deeper muscle tissues. Using specialized electronic circuits for amplification and filtering can help develop simple but effective systems for detecting and analyzing these signals. However, EMG devices developed by research teams frequently lack rigorous methodologies for validating the quality of the signals they record compared to those obtained by commercial systems that have undergone extensive testing and regulatory approval for market release.

View Article and Find Full Text PDF
Article Synopsis
  • The StartReact test is a noninvasive method used to evaluate the functioning of cortico-reticular pathways, but more research is needed on how different stimuli affect motor output.
  • A study examined the response of elbow flexor muscles in adults (ages 26-48) to three types of stimuli: visual only, audio-visual, and startle-inducing audio-visual, using surface electromyography (EMG) to measure muscle activity.
  • Results showed that reaction times were significantly faster and muscle activity was highest following startle-inducing stimuli, indicating that these stimuli may lead to both subcortical and cortical improvements in motor response.
View Article and Find Full Text PDF

Elastic contribution of polymeric fluids augments salinity-gradient-induced electric potential across a microfluidic channel.

J Colloid Interface Sci

January 2025

Department of Mechanical Engineering, IIT Kharagpur, Kharagpur 721302, India; Advanced Technology Development Centre, IIT Kharagpur, Kharagpur 721302, India. Electronic address:

Hypothesis: Harnessing electrical energy from salinity gradients, particularly for powering micro and nanoscale devices, has become a focal point of recent research attention, due to its renewable and biocompatible nature. Much of the reported research in that direction revolves around optimizing the membrane architecture and the charge distribution to maximize the induced electric potential, with no particular emphasis on the fluid rheology. However, many of the modern miniature systems, typically the bio-inspired ones, concern fluids with complex rheological characteristics, where the results for Newtonian solvents may not trivially apply.

View Article and Find Full Text PDF

With the transformation and development of the automotive industry, low-cost and seamless indoor and outdoor positioning has become a research hotspot for modern vehicles equipped with in-vehicle infotainment systems, Internet of Vehicles, or other intelligent systems (such as Telematics Box, Autopilot, etc.). This paper analyzes modern vehicles in different configurations and proposes a low-cost, versatile indoor non-visual semantic mapping and localization solution based on low-cost sensors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!