Objective: Hundreds of scientific publications are produced annually that involve the measurement of cortisol in saliva. Intra- and inter-laboratory variation in salivary cortisol results has the potential to contribute to cross-study inconsistencies in findings, and the perception that salivary cortisol results are unreliable. This study rigorously estimates sources of measurement variability in the assay of salivary cortisol within and between established international academic-based laboratories that specialize in saliva analyses. One hundred young adults (Mean age: 23.10 years; 62 females) donated 2 mL of whole saliva by passive drool. Each sample was split into multiple- 100 µL aliquots and immediately frozen. One aliquot of each of the 100 participants' saliva was transported to academic laboratories (N = 9) in the United States, Canada, UK, and Germany and assayed for cortisol by the same commercially available immunoassay.

Results: 1.76% of the variance in salivary cortisol levels was attributable to differences between duplicate assays of the same sample within laboratories, 7.93% of the variance was associated with differences between laboratories, and 90.31% to differences between samples. In established-qualified laboratories, measurement error of salivary cortisol is minimal, and inter-laboratory differences in measurement are unlikely to have a major influence on the determined values.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5598071PMC
http://dx.doi.org/10.1186/s13104-017-2805-4DOI Listing

Publication Analysis

Top Keywords

salivary cortisol
20
measurement cortisol
8
cortisol saliva
8
measurement error
8
cortisol
7
measurement
6
laboratories
6
saliva
5
salivary
5
saliva comparison
4

Similar Publications

Blood Flow Restricted Resistance Exercise in Well-Trained Men: Salivary Biomarker Responses and Oxygen Saturation Kinetics.

J Strength Cond Res

December 2024

Jayhawk Athletic Performance Laboratory, Wu Tsai Human Performance Alliance, University of Kansas, Lawrence, Kansas.

Eserhaut, DA, DeLeo, JM, and Fry, AC. Blood flow restricted resistance exercise in well-trained men: Salivary biomarker responses and oxygen saturation kinetics. J Strength Cond Res 38(12): e716-e726, 2024-Resistance exercise with continuous lower-limb blood flow restriction (BFR) may provide supplementary benefit to highly resistance-trained men.

View Article and Find Full Text PDF

Introduction: Colonoscopy is currently the most commonly used and effective method for early detection, diagnosis and treatment of tumours of the colon and rectum. However, similar to other invasive procedures, it is associated with adverse reactions such as pain and abdominal distension. Electroacupuncture (EA) has been proposed as a potential treatment for relieving this discomfort; however, there is limited evidence supporting its efficacy.

View Article and Find Full Text PDF

Introduction: Cortisol is an essential stress hormone and failure of its production, known as adrenal insufficiency (AI), is associated with significant mortality due to adrenal crisis. The Short Synacthen Test (SST) is the current diagnostic test of choice for AI, but it is both invasive and resource intensive. Globally, there is an unmet need for a non-invasive, cost-effective test.

View Article and Find Full Text PDF

.

Compr Psychoneuroendocrinol

November 2024

School of Social Sciences, University of Westminster, London, UK.

Cortisol awakening response (CAR) research relies upon self-collected saliva sampling during the post-awakening period. It is unknown how the CAR protocol is perceived and how they may affect typical routines relevant to CAR methodology. CAR assessment is sensitive to state variables, suggesting that CAR measurement may be affected by research participation.

View Article and Find Full Text PDF

There is a lack of objective indicators to evaluate the treatment effect of burning mouth syndrome, a neuropathic pain of unknown causes. Therefore, this study aimed to evaluate potential salivary biomarkers by analyzing saliva before and after clonazepam treatment in patients with burning mouth syndrome. Saliva was collected from 23 patients with burning mouth syndrome before and 4 weeks after the topical administration of clonazepam.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!