A Novel Pulse Measurement System by Using Laser Triangulation and a CMOS Image Sensor.

Sensors (Basel)

Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Rd., Taipei 106, Taiwan.

Published: December 2007

This paper presents a novel, non-invasive, non-contact system to measure pulsewaveforms of artery via applying laser triangulation method to detect skin surfacevibration. The proposed arterial pulsation measurement (APM) system chiefly consists of alaser diode and a low cost complementary metal-oxide semiconductor (CMOS) imagesensor. Laser triangulation and centroid method are combined with the Fast FourierTransform (FFT) in this study. The shape and frequency of the arterial pulsation can bedetected rapidly by using our APM system. The relative variation of the pulse at differentmeasurement points near wrist joint is used as a prognostic guide in traditional Chinesemedicine (TCM). An extensive series of experiments was conducted to evaluate theperformance of the designed APM system. From experimental results, the pulse amplitudeand frequency at the Chun point (related to the small intestine) of left hand showed anobvious increase after having food. In these cases, the peak to peak amplitudes and thefrequencies of arterial pulsations range from 38 to 48 μm and from 1.27 to 1.35 Hz,respectively. The height of arterial pulsations on the area near wrist joint can be estimatedwith a resolution of better than 4 μm. This research demonstrates that applying a CMOSimage sensor in designing a non-contact, portable, easy-to-use, low cost pulse measurementsystem is feasible. Also, the designed APM system is well suited for evaluating and pre-diagnosing the health of a human being in TCM clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3841900PMC
http://dx.doi.org/10.3390/s7123366DOI Listing

Publication Analysis

Top Keywords

apm system
16
laser triangulation
12
arterial pulsation
8
low cost
8
wrist joint
8
designed apm
8
arterial pulsations
8
system
6
novel pulse
4
pulse measurement
4

Similar Publications

This study presents a detailed analysis of the stability of weigh-in-motion sensors used at vehicle weighing stations. The objective of this research was a long-term assessment of reading variability, with a particular focus on the sensors' application in automated measurement stations. These investigations constitute a critical component of modern traffic management systems and vehicle overload control.

View Article and Find Full Text PDF

Faster and better than a physician?: Assessing diagnostic proficiency of ChatGPT in misdiagnosed individuals with neuromyelitis optica spectrum disorder.

J Neurol Sci

December 2024

The University of Texas Southwestern Medical Center, Department of Neurology, Neuroinnovation Program, Multiple Sclerosis & Neuroimmunology Imaging Program, Dallas, TX, USA; The University of Texas Southwestern Medical Center, Peter O'Donnell Jr. Brain Institute, Dallas, TX, USA. Electronic address:

Background: Neuromyelitis optica spectrum disorder (NMOSD) is a commonly misdiagnosed condition. Driven by cost-consciousness and technological fluency, distinct generations may gravitate towards healthcare alternatives, including artificial intelligence (AI) models, such as ChatGPT (Generative Pre-trained Transformer). Our objective was to evaluate the speed and accuracy of ChatGPT-3.

View Article and Find Full Text PDF

Aromatic-aromatic interactions drive fold switch of GA95 and GB95 with three residue difference.

Chem Sci

December 2024

Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan National Laboratory for Optoelectronics, Wuhan Institute of Physics and Mathematics, Innovation Academy of Precision Measurement, Chinese Academy of Sciences Wuhan 430071 China

Proteins typically adopt a single fold to carry out their function, but metamorphic proteins, with multiple folding states, defy this norm. Deciphering the mechanism of conformational interconversion of metamorphic proteins is challenging. Herein, we employed nuclear magnetic resonance (NMR), circular dichroism (CD), and all-atom molecular dynamics (MD) simulations to elucidate the mechanism of fold switching in proteins GA95 and GB95, which share 95% sequence homology.

View Article and Find Full Text PDF

Modifications of current psychometric models for analyzing test data are proposed that produce an additive scale measure of information. This information measure is a one-dimensional space curve or curved surface manifold that is invariant across varying manifold indexing systems. The arc length along a curve manifold is used as it is an additive metric having a defined zero and a version of the bit as a unit.

View Article and Find Full Text PDF

Background: A competency-based education approach calls for frequent workplace-based assessments (WBA) of Entrustable Professional Activities (EPAs). While mobile applications increase the efficiency, it is not known how many assessments are required for reliable ratings and whether the concept can be implemented in all sizes of residency programs.

Methods: Over 5 months, a mobile app was used to assess 10 different EPAs in daily clinical routine in Swiss anesthesia departments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!