Objectives: The aims of this study were to observe the pattern of transient motion after gadoxetic acid administration including incidence, onset, and duration, and to evaluate the clinical feasibility of free-breathing gadoxetic acid-enhanced liver magnetic resonance imaging using golden-angle radial sparse parallel (GRASP) imaging with respiratory gating.

Materials And Methods: In this institutional review board-approved prospective study, 59 patients who provided informed consents were analyzed. Free-breathing dynamic T1-weighted images (T1WIs) were obtained using GRASP at 3 T after a standard dose of gadoxetic acid (0.025 mmol/kg) administration at a rate of 1 mL/s, and development of transient motion was monitored, which is defined as a distinctive respiratory frequency alteration of the self-gating MR signals. Early arterial, late arterial, and portal venous phases retrospectively reconstructed with and without respiratory gating and with different temporal resolutions (nongated 13.3-second, gated 13.3-second, gated 6-second T1WI) were evaluated for image quality and motion artifacts. Diagnostic performance in detecting focal liver lesions was compared among the 3 data sets.

Results: Transient motion (mean duration, 21.5 ± 13.0 seconds) was observed in 40.0% (23/59) of patients, 73.9% (17/23) of which developed within 15 seconds after gadoxetic acid administration. On late arterial phase, motion artifacts were significantly reduced on gated 13.3-second and 6-second T1WI (3.64 ± 0.34, 3.61 ± 0.36, respectively), compared with nongated 13.3-second T1WI (3.12 ± 0.51, P < 0.0001). Overall, image quality was the highest on gated 13.3-second T1WI (3.76 ± 0.39) followed by gated 6-second and nongated 13.3-second T1WI (3.39 ± 0.55, 2.57 ± 0.57, P < 0.0001). Only gated 6-second T1WI showed significantly higher detection performance than nongated 13.3-second T1WI (figure of merit, 0.69 [0.63-0.76]) vs 0.60 [0.56-0.65], P = 0.004).

Conclusions: Transient motion developed in 40% (23/59) of patients shortly after gadoxetic acid administration, and gated free-breathing T1WI using GRASP was able to consistently provide acceptable arterial phase imaging in patients who exhibited transient motion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6080614PMC
http://dx.doi.org/10.1097/RLI.0000000000000409DOI Listing

Publication Analysis

Top Keywords

transient motion
24
gadoxetic acid
16
nongated 133-second
16
133-second t1wi
16
magnetic resonance
12
resonance imaging
12
acid administration
12
gated 133-second
12
gated 6-second
12
6-second t1wi
12

Similar Publications

Single-point mutations are pivotal in molecular zoology, shaping functions and influencing genetic diversity and evolution. Here we study three such genetic variants of a mechano-responsive protein, cadherin-23, that uphold the structural integrity of the protein, but showcase distinct genotypes and phenotypes. The variants exhibit subtle differences in transient intra-domain interactions, which in turn affect the anti-correlated motions among the constituent β-strands.

View Article and Find Full Text PDF

The transmission of virus-containing droplets among multiple people in an outdoor environment is seldom evaluated. In this study, an Euler-Lagrange computational fluid dynamics approach was used to investigate the effects of evaporation and the body thermal plume on the dispersion of coughed droplets under various wind conditions, and the infection risk was evaluated for various arrangements of individuals queuing outdoors using virtual manikin models. The evaporation time was longer for larger droplets and in a more humid environment.

View Article and Find Full Text PDF

Background And Objective: Radiosurgery can serve as a primary, adjuvant, or salvage treatment modality for cavernous sinus tumors (CST), providing high tumor control. However, particularly with cavernous sinus expansion, there may be insufficient distance from the optic apparatus to perform radiosurgery safely. The internal carotid artery adjacent to the distal dural ring (ICAddr), when enhancing similarly to the CST, can be difficult to delineate, and can lead to over-contouring of target volume near the optic nerve and therefore increasing the risk of radiation-induced optic toxicity.

View Article and Find Full Text PDF

A dynamic variant of Takotsubo cardiomyopathy mimicking apical hypertrophic cardiomyopathy: a case report.

Eur Heart J Case Rep

January 2025

Cardiovascular and Thoracic Division, Cardiology Department, University Hospital Southampton, Tremona Road, Southampton SO16 6YD, UK.

Background: Takotsubo cardiomyopathy usually presents with acute reversible left ventricular apical hypokinesia and apical ballooning with basal hyperdynamic function. We describe an underreported case of Takotsubo cardiomyopathy (TCM), misinterpreted as apical hypertrophic cardiomyopathy (HCM) due to transient apical oedema in the recovery phase of the condition.

Case Summary: A 74-year-old Caucasian woman, presented to the emergency department complaining of retrosternal chest pain following, emotional stress.

View Article and Find Full Text PDF

Quantum Dynamics Simulations of Exciton Polariton Transport.

Nano Lett

January 2025

Department of Chemistry, University of Rochester, Rochester, New York 14627, United States.

Recent experiments have shown that exciton transport can be significantly enhanced through hybridization with confined photonic modes in a cavity. The light-matter hybridization generates exciton-polariton (EP) bands, whose group velocity is significantly larger than the excitons. Dissipative mechanisms that affect the constituent states of EPs, such as exciton-phonon coupling and cavity loss, have been observed to reduce the group velocities in experiments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!