One of the major issues in time-critical medical applications using wireless technology is the size of the payload packet, which is generally designed to be very small to improve the transmission process. Using small packets to transmit continuous ECG data is still costly. Thus, data compression is commonly used to reduce the huge amount of ECG data transmitted through telecardiology devices. In this paper, a new ECG compression scheme is introduced to ensure that the compressed ECG segments fit into the available limited payload packets, while maintaining a fixed CR to preserve the diagnostic information. The scheme automatically divides the ECG block into segments, while maintaining other compression parameters fixed. This scheme adopts discrete wavelet transform (DWT) method to decompose the ECG data, bit-field preserving (BFP) method to preserve the quality of the DWT coefficients, and a modified running-length encoding (RLE) scheme to encode the coefficients. The proposed dynamic compression scheme showed promising results with a percentage packet reduction (PR) of about 85.39% at low percentage root-mean square difference (PRD) values, less than 1%. ECG records from MIT-BIH Arrhythmia Database were used to test the proposed method. The simulation results showed promising performance that satisfies the needs of portable telecardiology systems, like the limited payload size and low power consumption.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10916-017-0817-1 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Department of Cardiovascular Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
Background: This study aimed to compare inappropriate shock (IAS) rates between subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (TV-ICD) in Brugada syndrome (BrS) patients and identify risk factors for IAS in S-ICD use.
Methods: We enrolled consecutive patients with BrS who underwent ICD implantation between 2013 and 2023. Data on clinical characteristics, S-ICD screening test data, and IAS occurrence were retrospectively analyzed.
JMIR Form Res
January 2025
Department of Computer Science, University of California, Irvine, Irvine, CA, United States.
Background: Acute pain management is critical in postoperative care, especially in vulnerable patient populations that may be unable to self-report pain levels effectively. Current methods of pain assessment often rely on subjective patient reports or behavioral pain observation tools, which can lead to inconsistencies in pain management. Multimodal pain assessment, integrating physiological and behavioral data, presents an opportunity to create more objective and accurate pain measurement systems.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Emergency Department, Habib bourguiba university hospital, Faculty of Medicine, Sfax University, Majida Boulila Avenue, Sfax, Tunisia.
Introduction: Electrical injuries (EIs) represent a significant clinical challenge due to their complex pathophysiology and variable presentation, ranging from minor burns to severe internal organ damage. Despite their prevalence in both; domestic and occupational settings, there remains a rareness of systematic guidelines and comprehensive literature to aid clinicians in effectively managing these injuries. Understanding these factors is crucial for developing protocols that can mitigate the risk of delayed complications, such as cardiac arrhythmias, in patients who initially appear stable.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
January 2025
Department of Cardiology, Xinhua Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Objective: To compare the paced QRS duration on different sites in age-, gender-, and indication-matched patients implanted with Micra leadless pacemakers and conventional transvenous pacemakers (TV-PM).
Method: A total of 82 patients from Xinhua Hospital, Shanghai Jiaotong University, were enrolled, including two groups of 41 patients matched according to gender, age, and pacemaker indications, who underwent Micra and TV-PM implantations, respectively. The baseline data of the patients, the pacing site described using three- and nine-partition methods, and the paced QRS duration on 12-lead electrocardiogram were then analyzed.
J Inflamm Res
January 2025
Institute of Nephrology, Zhongda Hospital, Southeast University School of Medicine, Nanjing, Jiangsu, 210009, People's Republic of China.
Objective: This study evaluated the diagnostic value of plasma Neutrophil extracellular traps (NETs) levels and the index of cardiac electrophysiological balance (iCEB) in identifying silent myocardial ischemia (SMI) in maintenance hemodialysis (MHD) patients.
Methods: This cross-sectional observational study involved patients receiving MHD treatment. Data were collected on coronary angiography performed in our hospital from February 2023 to February 2024.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!