The management of heart failure patients presenting in a moribund state remains challenging, despite significant advances in the field of ventricular assist systems. Bridge to decision involves using temporary devices to stabilize the hemodynamic state of such patients while further assessment is performed and a decision can be made regarding patient management. We developed a new temporary left ventricular assist system employing a disposable centrifugal pump with a hydrodynamically levitated bearing. We used three adult goats (body weight, 58-68 kg) to investigate the 30-day performance and hemocompatibility of the newly developed left ventricular assist system, which included the pump, inflow and outflow cannulas, the extracorporeal circuit, and connectors. Hemodynamic, hematologic, and blood chemistry measurements were investigated as well as end-organ effect on necropsy. All goats survived for 30 days in good general condition. The blood pump was operated at a rotational speed of 3000-4500 rpm and a mean pump flow of 3.2 ± 0.6 L min. Excess hemolysis, observed in one goat, was due to the inadequate increase in pump rotational speed in response to drainage insufficiency caused by continuous contact of the inflow cannula tip with the left ventricular septal wall in the early days after surgery. At necropsy, no thrombus was noted in the pump, and no damage caused by mechanical contact was found on the bearing. The newly developed temporary left ventricular assist system using a disposable centrifugal pump with hydrodynamic bearing demonstrated consistent and satisfactory hemodynamic performance and hemocompatibility in the goat model.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-017-0989-yDOI Listing

Publication Analysis

Top Keywords

left ventricular
20
ventricular assist
20
assist system
16
temporary left
12
hydrodynamically levitated
8
levitated bearing
8
pump
8
bridge decision
8
goat model
8
developed temporary
8

Similar Publications

Introduction: Decreased left atrial appendage emptying velocity (LAAV) is a marker for thrombus formation. This study evaluates the association between LAAV and inflammatory indices in non-valvular atrial fibrillation (AF) patients.

Methods: The study population was 1428 patients with AF, 875 of whom enrolled.

View Article and Find Full Text PDF

Ventricular arrhythmias induced by ischemia/reperfusion injury limits the therapeutic effect of early reperfusion therapy for acute myocardial infarction. This study investigated the protective effects of the β2-adrenergic receptor (β2-AR) agonist clenbuterol against ischemia/reperfusion-induced arrhythmias and the underlying mechanism. Anesthetized rats were subjected to 10-min left coronary artery occlusion and 10-min reperfusion in vivo.

View Article and Find Full Text PDF

Background: Primary aldosteronism (PA) is the leading surgically treatable cause of hypertension, with adrenalectomy as the definitive treatment for unilateral PA (UPA). However, some patients have persistent hypertension after surgery. This study aims to identify preoperative factors affecting surgical outcomes and develop a predictive model for postoperative hypertension resolution.

View Article and Find Full Text PDF

Background: Changes in cardiac function and structure as well as their association with the cardiac autonomic nervous system remain incompletely characterized in children with stage 5 chronic kidney disease (CKD) receiving hemodialysis (HD).

Methods: A prospective observational cohort study was conducted on 40 Egyptian children with CKD on regular HD compared to 40 age- and sex-matched healthy children. All participants underwent thorough clinical examination, laboratory investigations, 24-h Holter monitoring, and 2D/4D echocardiographic study (conventional and advanced modalities).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!