The ability to perceive motion is one of the main properties of the visual system. Sensitivity in detecting coherent motion has been thoroughly investigated in humans, where thresholds for motion detection are well below 10% of coherence, i.e. of the proportion of dots coherently moving in the same direction, among a background of randomly moving dots. Equally low thresholds have been found in other species, including monkeys, cats and seals. Given the lack of data from the domestic dog, we tested 5 adult dogs on a conditioned discrimination task with random dot displays. In addition, five adult humans were tested in the same condition for comparative purposes. The mean threshold for motion detection in our dogs was 42% of coherence, while that of humans was as low as 5%. Therefore, dogs have a much higher threshold of coherent motion detection than humans, and possibly also than phylogenetically closer species that have been tested in similar experimental conditions. Various factors, including the relative role of global and local motion processing and experience with the experimental stimuli may have contributed to this result. Overall, this finding questions the general claim on dogs' high performance in detecting motion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5595918 | PMC |
http://dx.doi.org/10.1038/s41598-017-11864-z | DOI Listing |
Hear Res
January 2025
Columbia University Irving Medical Center, Department of Otolaryngology, Head and Neck Surgery, 180 Fort Washington Ave, New York, 10032, NY, USA; Columbia University, Department of Biomedical Engineering, 1210 Amsterdam Ave, New York, 10027, NY, USA.
Sound-evoked displacement responses at the outer hair cell-Deiters' cell junction (OHC-DC) are of significant interest in cochlear mechanics, as OHCs are believed to be in part responsible for active tuning enhancement and amplification. Motion in the cochlea is three-dimensional, and the architecture of the organ of Corti complex (OCC) suggests the presence and mechanical importance of all three components of motion. Optical coherence tomography (OCT) displacement measurements of OHC-DC motion from different experimental preparations often show disparate results, potentially due to OCT measuring only the motion component along the beam axis.
View Article and Find Full Text PDFJ Phys Chem A
January 2025
Department of Chemistry, University of Malaya, 50603 Kuala Lumpur, Malaysia.
This study investigates the motion of an electron in a Coulomb potential driven by an intense linearly polarized XUV laser pulse analyzed using Gordon-Volkov wave functions. The wave function is decomposed into spherical partial waves to model the scattered electron wave packet after the recollision with a proton. This interaction triggers high harmonic generation, producing coherent X-ray pulses with frequencies that are integer multiples of the XUV field.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Ophthalmology and Visual Sciences, University of British Columbia, Vancouver, BC, Canada.
People with amblyopia show deficits in global motion perception, especially at slow speeds. These observers are also known to have unstable fixation when viewing stationary fixation targets, relative to healthy controls. It is possible that poor fixation stability during motion viewing interferes with the fidelity of the input to motion-sensitive neurons in visual cortex.
View Article and Find Full Text PDFMicromachines (Basel)
January 2025
Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe's optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Chemistry & Environmental Science, Jordan Hu College of Science and Liberal Arts, New Jersey Institute of Technology, Newark, NJ, 07102, USA.
Nanoparticles (NPs) have been successfully used as drug delivery systems. To develop and optimize NP-based drug delivery systems, it is essential to understand the dynamics of cell-NP interactions. Quantitative phase imaging techniques enable label-free imaging and have the potential to reveal how cells interact with NPs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!