Dogs are not better than humans at detecting coherent motion.

Sci Rep

Laboratory of Applied Ethology, Dipartimento di Biomedicina Comparata e Alimentazione, University of Padova, Viale dell'Università 16, 35020, Legnaro, (PD), Italy.

Published: September 2017

The ability to perceive motion is one of the main properties of the visual system. Sensitivity in detecting coherent motion has been thoroughly investigated in humans, where thresholds for motion detection are well below 10% of coherence, i.e. of the proportion of dots coherently moving in the same direction, among a background of randomly moving dots. Equally low thresholds have been found in other species, including monkeys, cats and seals. Given the lack of data from the domestic dog, we tested 5 adult dogs on a conditioned discrimination task with random dot displays. In addition, five adult humans were tested in the same condition for comparative purposes. The mean threshold for motion detection in our dogs was 42% of coherence, while that of humans was as low as 5%. Therefore, dogs have a much higher threshold of coherent motion detection than humans, and possibly also than phylogenetically closer species that have been tested in similar experimental conditions. Various factors, including the relative role of global and local motion processing and experience with the experimental stimuli may have contributed to this result. Overall, this finding questions the general claim on dogs' high performance in detecting motion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5595918PMC
http://dx.doi.org/10.1038/s41598-017-11864-zDOI Listing

Publication Analysis

Top Keywords

coherent motion
12
motion detection
12
detecting coherent
8
motion
8
humans
5
dogs
4
dogs better
4
better humans
4
humans detecting
4
motion ability
4

Similar Publications

Narrow elliptical motion at the outer hair cell-Deiters' cell junction explains disparate features of uniaxial displacement measurements.

Hear Res

January 2025

Columbia University Irving Medical Center, Department of Otolaryngology, Head and Neck Surgery, 180 Fort Washington Ave, New York, 10032, NY, USA; Columbia University, Department of Biomedical Engineering, 1210 Amsterdam Ave, New York, 10027, NY, USA.

Sound-evoked displacement responses at the outer hair cell-Deiters' cell junction (OHC-DC) are of significant interest in cochlear mechanics, as OHCs are believed to be in part responsible for active tuning enhancement and amplification. Motion in the cochlea is three-dimensional, and the architecture of the organ of Corti complex (OCC) suggests the presence and mechanical importance of all three components of motion. Optical coherence tomography (OCT) displacement measurements of OHC-DC motion from different experimental preparations often show disparate results, potentially due to OCT measuring only the motion component along the beam axis.

View Article and Find Full Text PDF

Attosecond Rescattering of Laser-Assisted Electron-Proton Collision in Coulomb Potential.

J Phys Chem A

January 2025

Department of Chemistry, University of Malaya, 50603 Kuala Lumpur, Malaysia.

This study investigates the motion of an electron in a Coulomb potential driven by an intense linearly polarized XUV laser pulse analyzed using Gordon-Volkov wave functions. The wave function is decomposed into spherical partial waves to model the scattered electron wave packet after the recollision with a proton. This interaction triggers high harmonic generation, producing coherent X-ray pulses with frequencies that are integer multiples of the XUV field.

View Article and Find Full Text PDF

People with amblyopia show deficits in global motion perception, especially at slow speeds. These observers are also known to have unstable fixation when viewing stationary fixation targets, relative to healthy controls. It is possible that poor fixation stability during motion viewing interferes with the fidelity of the input to motion-sensitive neurons in visual cortex.

View Article and Find Full Text PDF

This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe's optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging.

View Article and Find Full Text PDF

Imaging cells and nanoparticles using modulated optically computed phase microscopy.

Sci Rep

January 2025

Department of Chemistry & Environmental Science, Jordan Hu College of Science and Liberal Arts, New Jersey Institute of Technology, Newark, NJ, 07102, USA.

Nanoparticles (NPs) have been successfully used as drug delivery systems. To develop and optimize NP-based drug delivery systems, it is essential to understand the dynamics of cell-NP interactions. Quantitative phase imaging techniques enable label-free imaging and have the potential to reveal how cells interact with NPs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!