Objective With the implementation of the K-DOQI guidelines, more patients are in need of long-term dialysis catheters until maturation of the arteriovenous fistula. However, on occasion, when placing a tunneled cuffed catheter for hemodialysis, we have encountered difficulty with passing the guidewire in spite of demonstration of a patent cervical portion of the internal jugular vein on duplex. Herein, we review our experience with intraoperative venoplasty for placement of Tesio™ catheters (Medcomp Harleysville, PA). Methods Of the 1147 Tesio™ catheters placed since 1997 by our service, 35 venograms were performed due to difficulty encountered with placement of the guidewire. Patent veins were all crossed with the use of angle-guiding catheters, angled glidewires, and a torque vise. If chronically occluded intrathoracic veins were identified, an alternate site was selected for the placement of the Tesio™ catheter. Results Of the 35 cases with difficulty in catheter placement, venogram demonstrated a patent but tortuous vein in 9, chronically occluded intrathoracic veins in 6, and severe stenosis of the intrathoracic veins in 20. In 19 cases with severe stenosis of the intrathoracic veins, balloon angioplasty with an 8-mm balloon was successfully performed, which allowed successful placement of a functional Tesio™ catheter. In the additional one case, the catheter was not able to be placed despite angioplasty. Seven lesions that underwent balloon angioplasty were in the innominate vein, 11 were in the proximal internal jugular vein, and two were in the superior vena cava. Conclusion Venous balloon angioplasty can be used to maintain options for the site of access for tunneled cuffed catheters and may be necessary to assist with placement of long term cuffed dialysis catheters.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1708538117728866DOI Listing

Publication Analysis

Top Keywords

intrathoracic veins
16
balloon angioplasty
12
intraoperative venoplasty
8
dialysis catheters
8
tunneled cuffed
8
internal jugular
8
jugular vein
8
placement tesio™
8
tesio™ catheters
8
chronically occluded
8

Similar Publications

Vascular abnormalities not to miss on routine chest CT: A pictorial review.

Eur J Radiol

January 2025

Department of Radiology, Liverpool Heart and Chest NHS Foundation Trust, Thomas Drive, Liverpool, UK; Liverpool Centre for Cardiovascular Science, Liverpool, UK. Electronic address:

There is a wide and ever-increasing range of imaging indications for thoracic computed tomography (CT). Identifying and appropriately triaging cardiovascular findings is often challenging, especially in non-gated or unenhanced studies. The authors provide a pictorial review of clinically relevant abnormalities of the main intrathoracic vessels (aorta, superior vena cava, pulmonary arteries and coronary arteries), for radiologists reporting non-gated enhanced or unenhanced CT of the thorax.

View Article and Find Full Text PDF

Rationale: Intravenous catheter placement in the healthy upper extremity is preferred for chemotherapy in patients with breast cancer. Common venous accesses are peripherally inserted central catheters (PICCs) and totally implantable intravenous port catheters (TIVPs). In this case, a patient with breast cancer had a history of infusion port placement through the left internal jugular vein, with ipsilateral innominate vein stenosis after placement.

View Article and Find Full Text PDF
Article Synopsis
  • A case of arterial cerebral air embolism (aCAE) in an 84-year-old male is reported, likely caused by aspiration pneumonia, which led to sudden loss of consciousness.
  • CT scans showed air presence in specific brain areas and indicated right upper lung aspiration pneumonia with cavity formation.
  • The condition was treated with an antiepileptic, and since there was no prior medical intervention, it was classified as noniatrogenic aCAE, highlighting the rarity of such cases compared to more common iatrogenic ones.
View Article and Find Full Text PDF

Background: Radiographic assessment of the intrathoracic caudal vena cava (CVC) is commonly used to evaluate hemodynamic status in veterinary patients without and with pulmonary, pericardial, or right-sided cardiac diseases. Many of these patients are now commonly evaluated with computed tomography (CT) in both emergency and referral settings. Traditional radiographic ratios in dogs, particularly the CVC height/aorta height (CVC/Ao) ratio, are often extrapolated to CT in order to determine if the CVC is normal in size.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!