Soft Tissue Foreign Body: Utility of High Resolution Ultrasonography.

J Clin Diagn Res

Senior Resident, Department of Radiodiagnosis, K V G Medical College and Hospital, Sullia, Dakshina Kannada, Karnataka, India.

Published: July 2017

AI Article Synopsis

  • High Resolution Ultrasonography (HRUSG) can effectively diagnose and localize retained wooden foreign bodies, which are often not visible in traditional imaging.
  • The study involved 46 patients with foreign body injuries, where HRUSG was used after initial radiography, leading to a significant detection rate of foreign bodies and related inflammatory responses.
  • With a sensitivity and negative predictive value of 100%, HRUSG proves to be an efficient tool for both diagnosis and surgical guidance in foreign body removal.

Article Abstract

Introduction: Minor percentage of wooden foreign bodies is radio-opaque. High Resolution Ultrasonography (HRUSG) though existing is sparsely used as a primary imaging modality for diagnosis and localization of retained foreign body.

Aim: To evaluate the diagnostic accuracy of High Resolution Ultrasonography (HRUSG) in diagnoses and localization of retained foreign body.

Materials And Methods: A prospective study with registered 46 patients with history of foreign body injury which were initially imaged with conventional radiography was enrolled. Later patients were subjected for high resolution USG of the diseased part with a linear transducer. Surface marking was done for all subjects to assist the surgical exploration. Ultrasound findings were correlated with surgical exploration and histopathological findings.

Results: Out of 46 patients, forty one showed foreign body with foreign body inflammatory reaction in the form of abscess and/or granulation tissue on high resolution ultrasonography. No foreign body was detected in five patients but they showed focal hypoechogenicity which represented abscess and/or haematoma. On surgical exploration, two out of 41 patients did not reveal foreign body where as rest were found to have foreign body with foreign body inflammatory reaction. Sensitivity and negative predictive value of the current study is 100%.

Conclusion: High resolution USG is not only an efficient modality in diagnosing and localizing the foreign body in soft tissue, but can also be utilized for guiding the foreign body removal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5583796PMC
http://dx.doi.org/10.7860/JCDR/2017/26384.10269DOI Listing

Publication Analysis

Top Keywords

foreign body
40
high resolution
24
resolution ultrasonography
16
foreign
13
surgical exploration
12
body
10
soft tissue
8
ultrasonography hrusg
8
localization retained
8
retained foreign
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!