The quantitative analysis accuracy of calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is severely affected by the self-absorption effect and estimation of plasma temperature. Herein, a CF-LIBS quantitative analysis method based on the auto-selection of internal reference line and the optimized estimation of plasma temperature is proposed. The internal reference line of each species is automatically selected from analytical lines by a programmable procedure through easily accessible parameters. Furthermore, the self-absorption effect of the internal reference line is considered during the correction procedure. To improve the analysis accuracy of CF-LIBS, the particle swarm optimization (PSO) algorithm is introduced to estimate the plasma temperature based on the calculation results from the Boltzmann plot. Thereafter, the species concentrations of a sample can be calculated according to the classical CF-LIBS method. A total of 15 certified alloy steel standard samples of known compositions and elemental weight percentages were used in the experiment. Using the proposed method, the average relative errors of Cr, Ni, and Fe calculated concentrations were 4.40%, 6.81%, and 2.29%, respectively. The quantitative results demonstrated an improvement compared with the classical CF-LIBS method and the promising potential of in situ and real-time application.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0003702817734293DOI Listing

Publication Analysis

Top Keywords

internal reference
16
plasma temperature
16
quantitative analysis
12
estimation plasma
12
calibration-free laser-induced
8
laser-induced breakdown
8
breakdown spectroscopy
8
spectroscopy cf-libs
8
cf-libs quantitative
8
analysis method
8

Similar Publications

Aneurysmal rupture in microscopic polyangiitis: a case-based review.

Clin Rheumatol

January 2025

Department of Medical Laboratory Science, Faculty of Health Sciences, Hokkaido University, Sapporo, Hokkaido, Japan.

Microscopic polyangiitis (MPA) affects small and medium vessel, which sometimes leads to arterial aneurysms. In English database, only 15 reports refer to ruptured aneurysms in MPA. We experienced a fatal case with MPA who developed multiple visceral aneurysms, resulting in rupture of the hepatic aneurysm.

View Article and Find Full Text PDF

Contrast-enhanced US of High-Risk Indeterminate Focal Liver Observations Categorized as LR-4 or LR-M at CT/MRI.

Radiology

January 2025

From the Department of Radiology, Thomas Jefferson University Hospital, 132 S 10th St, 763G Main Bldg, Philadelphia, PA 19107 (A.L., C.K.Y.E., T.S.X., S.K.R., C.E.W., K.B., J.R.E., F.F.); Division of Internal Medicine, Hepatobiliary and Immunoallergic Diseases, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy (F.P.); Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy (F.P.); University of California San Diego, San Diego, Calif (Y.K.); University of Calgary, Calgary, Canada (A.M.K., S.R.W.); Einstein Medical Center, Philadelphia, Pa (S.K.R.); Vanderbilt University, Nashville, Tenn (V.P.); Stanford University, Stanford, Calif (A.K.); UT Southwestern Medical Center, Dallas, Tex (D.T.F.); Department of Visceral Surgery and Medicine, Bern University Hospital, University of Bern, Bern, Switzerland (A.B., I.P.R.); Department of Imaging Sciences, School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and Medicine, King's College London, London, United Kingdom (P.S.S.); and Department of Radiology, King's College Hospital, London, United Kingdom (P.S.S.).

Background Indeterminate focal liver observations in patients at risk for hepatocellular carcinoma (HCC) may require invasive biopsy or follow-up, which could lead to delays in definitive categorization and to postponement of treatment. Purpose To examine clinical effect of contrast-enhanced US (CEUS) in participants with high-risk indeterminate liver observations categorized as Liver Imaging Reporting and Data System (LI-RADS) category LR-4 (probably HCC) or LI-RADS category LR-M (probably or definitely malignant but not HCC specific) at CT or MRI. Materials and Methods This was a secondary analysis of a prospective international multicenter validation study for CEUS LI-RADS (January 2018 to August 2021).

View Article and Find Full Text PDF

This study reports a novel ratiometric fluorescence sensor based on a tetraphenylethylene-bipyridine covalent organic framework (TPE-Bpy-COF) for the sensitive detection of Cu, leveraging the unique coordination properties of the bipyridine moieties. The interaction between Cu and the nitrogen atoms in the bipyridine units induces fluorescence quenching at 500 nm through an efficient host-guest electron transfer mechanism, where excited-state electrons from the COF framework are transferred to the vacant orbitals of Cu. Upon excitation at 410 nm, the sensor exhibits a primary emission peak at 500 nm, which is quenched in the presence of Cu, while an overtone peak at 820 nm remains stable, serving as an internal reference for ratiometric measurements and significantly enhancing the accuracy and reliability of the sensor.

View Article and Find Full Text PDF

An accurate diagnosis of invasive aspergillosis (IA) in patients with underlying hematological malignancies relies heavily on galactomannan detection. In this study, we compared the VirCLIA chemiluminescence immunoassay (CLIA) with the frequently used Platelia enzyme-linked immunosorbent assay (ELISA) on serum from hematology patients with suspected IA. Patients were categorized according to EORTC/MSGERC 2020 definitions into proven/probable IA and possible/no IA.

View Article and Find Full Text PDF

Autoimmune polyglandular syndromes (APS) are characterized by associations of two or more autoimmune diseases (AID). APS type 3 is characterized by the presence of autoimmune thyroid disease associated with other AID, excluding adrenal gland involvement. Here we report a case of a 64-year-old male, with history of type 1 diabetes mellitus (T1DM), diagnosed at the age of 32, who was referred to a Diabetes consultation in 2014 due to poor metabolic control.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!