A cohort evaluation of clinical use and performance characteristics of Ambu AuraGain™: A prospective observational study.

Indian J Anaesth

Department of Anaesthesiology, Lokmanya Tilak Municipal General Hospital, Lokmanya Tilak Municipal Medical College, Mumbai, Maharashtra, India.

Published: August 2017

Background And Aims: Ambu AuraGain™ (AG) (Ambu, Ballerup, Denmark) is a supraglottic device which has a design facilitating its use as a conduit for intubation. We designed this prospective observational study to assess the ease of AG placement in paralysed patients, determine its position and alignment to the glottis and assess its utility as a conduit for intubation.

Methods: One hundred patients, aged 18-60 years, American Society of Anesthesiologists physical status I-II, undergoing elective surgery under general anaesthesia were included in the study. The ease and number of attempts for successful insertion, ease of gastric tube insertion, leak pressures, fibre-optic grade of view, number of attempts and time for tracheal intubation, time for AG removal and complications were recorded. The mean, standard deviation (SD), interquartile range (IQR) and range were calculated. The upper limit of confidence interval for overall failure rate was calculated using Wilson's score method.

Results: AG was successfully inserted in all patients. The mean (SD) time taken for insertion was 17.32 (8.48) s. The median [IQR] leak pressures were 24 [20-28] cm of HO. Optimal laryngeal view for intubation was obtained in 68 patients. Eighty-eight patients could be intubated in the first attempt. Five patients could not be intubated. The overall failure rate of device was 9%.

Conclusion: AMBU AuraGain™ serves as an effective ventilating aid, but caution is suggested before using it as a conduit for endotracheal intubation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5579853PMC
http://dx.doi.org/10.4103/ija.IJA_285_17DOI Listing

Publication Analysis

Top Keywords

ambu auragain™
12
prospective observational
8
observational study
8
number attempts
8
leak pressures
8
failure rate
8
patients intubated
8
patients
6
cohort evaluation
4
evaluation clinical
4

Similar Publications

Artificial intelligence improves bronchoscopy performance: a randomised crossover trial.

ERJ Open Res

January 2025

Copenhagen Academy for Medical Education and Simulation, Rigshospitalet, The Capital Region of Denmark, Copenhagen, Denmark.

Rationale: Flexible bronchoscopy is an operator-dependent procedure. An automatic bronchial identification system based on artificial intelligence (AI) could help bronchoscopists to perform more complete and structured procedures through automatic guidance.

Methods: 101 participants were included from six different continents at the European Respiratory Society annual conference in Milan, 9-13 September 2023.

View Article and Find Full Text PDF

Purpose: UGN-101, a reverse thermal mitomycin gel for upper tract instillation, recently became the first FDA approved treatment for upper tract urothelial carcinoma (UTUC). However, the durability of UGN-101 treatment has not been well described. Here we present long term outcomes from our multi-institutional cohort for patients who initially responded to treatment.

View Article and Find Full Text PDF

This article provides a comprehensive overview of the current treatment options for patients with metastatic castration-resistant prostate cancer (mCRPC) following the failure of first-line therapy. Although significant progress has been made in the primary treatment of hormone-sensitive prostate cancer, the management of mCRPC remains a clinical challenge. The article outlines the diagnostic criteria for mCRPC, which can be confirmed through biochemical progression and imaging techniques.

View Article and Find Full Text PDF

Understanding renal pelvis pressure (P) during ureteroscopy (URS) has become increasingly important. High irrigation rates, desirable to maintain visualization and limit thermal dose, can increase P. Use of a multi-channel ureteroscope (m-ureteroscope) with a dedicated drainage channel is one strategy that may facilitate simultaneous low P and high flowrate.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!