Background And Objectives: The release of metal ions from orthodontic appliances is part of the dissolution and biomechanical processes of alloys. Nickel (Ni) and chromium (Cr) are the elements commonly used in the manufacture of various components of fixed orthodontic appliances, including bands, brackets and wires. This study was aimed to measure the Ni and Cr ions levels in the scalp hair of patients treated with fixed orthodontic appliances in comparison of the control group.

Materials And Methods: The patient group consisted of 24 patients treated with fixed orthodontic appliances for one year, while the control group included 28 healthy individuals without orthodontic appliances. Analysis of the Cr and Ni was performed using atomic absorption spectrophotometer by graphite furnace method. The data were analyzed via student and paired samples t-test and ANOVA repeated measurement test.

Results: After one year, the levels of Ni and Cr in two groups showed significant differences (0.086 ± 0.007 and 0.258 ± 0.009 µg/g for control group and 0.149 ± 0.010 and 0.339 ± 0.013 µg/g for patient group, respectively for Ni and Cr, p < .001). ANCOVA test by removing the effects of age, gender and the baseline levels of Ni and Cr showed that changes in these ions in the scalp hair of both groups after one year were statistically significant.

Conclusion: Due to the slightly elevated levels of Ni and Cr ions in the scalp hair of patients treated with fixed orthodontic appliances and considering the cytotoxic and allergic effects of these ions, changing the ingredients in fixed orthodontic appliances is suggested for the future.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00016357.2017.1372624DOI Listing

Publication Analysis

Top Keywords

orthodontic appliances
20
fixed orthodontic
16
scalp hair
8
nickel chromium
8
patients treated
8
treated fixed
8
patient group
8
control group
8
orthodontic
6
appliances
5

Similar Publications

Introduction: This study aimed to assess the root resorption and alveolar bone changes of maxillary incisors volumetrically and 3-dimensionally in patients with Class II Division 1 malocclusion who underwent treatments involving the extraction of 4 first premolars with conventional fixed appliances (FAs) vs clear aligners (CAs).

Methods: A total of 320 maxillary incisors from 80 patients were assessed and divided into 2 groups (FAs and CAs), each possessing similar baseline characteristics. Pretreatment and posttreatment cone-beam computed tomography scans were used to analyze linear and volumetric orthodontically induced inflammatory root resorption, alveolar bone thickness (ABT), alveolar bone height (ABH), as well as anteroposterior and vertical movements of maxillary incisors.

View Article and Find Full Text PDF

This retrospective longitudinal outcome study comparing orthodontic extraction modalities, including extraction of maxillary first or second molars, aimed to compare the three-dimensional tooth movement of maxillary canines (C), premolars (P1, P2), and molars (M1, M2) in Class II division 1 malocclusion treatment with fixed appliances. A sample of 98 patients (mean age 13.20 ± 1.

View Article and Find Full Text PDF

Aim: This study evaluates long-term shear bond strength (SBS) and enamel micro cracks (MCs) healing after using adhesive pre-coated brackets (APC).

Materials And Methods: A total of eighty extracted human premolar teeth were randomly divided into four experimental groups ( = 20 per group): Control group: Teeth underwent indentation but no bracket bonding; group II : Teeth were subjected to indentation without exposure to thermocycling; group III: Teeth experienced both indentation and thermocycling; group IV: No indentation was applied to the teeth; groups III and IV were further divided into two subgroups to simulate different clinical timelines: Subgroup A (n = 10): Teeth underwent 5,000 thermocycles, equivalent to six months of clinical use. Subgroup B (n = 10): Teeth were subjected to 10,000 thermocycles, representing 12 months of use.

View Article and Find Full Text PDF

Aim: To evaluate risk indicators for gingival recessions (GRs) in the lower anterior teeth of orthodontic patients post treatment and during a retention period of at least 5 years, compared to non-treated controls.

Material And Methods: Eighty-nine orthodontically treated patients who were recession-free before treatment were recruited. Demographic, cephalometric and occlusal records were retrieved before (T1) and after treatment (T2), and periodontal outcomes were clinically evaluated at least 5 years post retention (T3).

View Article and Find Full Text PDF

Purpose: To examine the alterations in oral healthcare indicators subsequent to the administration of cetylpyridinium chloride.

Materials And Methods: In this retrospective study, clinical data of 58 patients who received orthodontic treatment using removable appliances at our medical facility were collected. Patients were divided into two groups based on whether they used cetylpyridinium chloride during orthodontic treatment: the combined group (n = 31, received 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!