A compendium of about 100 radiopharmaceuticals, based on the OLINDA/EXM version 2.0 software, is presented. A new generation of voxel-based, realistic human computational phantoms developed by the RADAR committee of the Society of Nuclear Medicine and Molecular Imaging, based on 2007 recommendations of the International Commission on Radiological Protection, was used to develop the dose estimates, and the most recent biokinetic models were used as well. These estimates will be made available in electronic form and can be modified and updated as models are changed and as new radiopharmaceuticals are added.