Increased fracture displacement has previously been described with the application of pelvic circumferential compression devices (PCCDs) in patients with lateral compression-type pelvic fracture. We describe the first reported case of hemodynamic deterioration temporally associated with the prehospital application of a PCCD in a patient with a complex acetabular fracture with medial displacement of the femoral head. Active hemorrhage from a site adjacent to the acetabular fracture was subsequently demonstrated on angiography. Caution in the application of PCCDs to patients with lateral compression-type fractures is warranted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amj.2017.05.006 | DOI Listing |
Eur Heart J Case Rep
January 2025
Department of Cardiology, Komaki City Hospital, 1-20 Joubushi, Komaki, Aichi 485-8520, Japan.
Background: Transcatheter aortic valve implantation (TAVI) is a safe and effective therapy for patients with severe aortic stenosis. A Stuck leaflet and severe intraprosthetic regurgitation after valve implantation occur rarely but can lead to sudden haemodynamic deterioration. We encountered a case of a stuck leaflet following post-dilatation with the Edwards Sapien 3 Ultra RESILIA valve.
View Article and Find Full Text PDFAm J Cardiol
January 2025
Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland. Electronic address:
Transcatheter edge-to-edge repair (TEER) is an effective intervention for high-risk patients with severe symptomatic mitral regurgitation (MR), but its acute impact on left ventricular (LV) function has not been well studied using advanced echocardiographic techniques. This study investigated the immediate effects of TEER on LV volumes and functions, as well as their influence on mid-term outcomes, using high-resolution 3D transesophageal echocardiography. In 80 patients undergoing TEER for severe MR (mean age 79±8 years, 49% with primary MR), LV end-diastolic volume (LVEDV) and stroke volume significantly decreased (161±61 to 147±54 ml and 69±18 to 50±15 ml, respectively), while end-systolic volume increased (92±60 to 97±45 ml; p<0.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
Department of Cardiovascular Medicine, National Cerebral & Cardiovascular Center, Suita, Japan.
Background: The Society of Cardiovascular Angiography and Intervention (SCAI) has defined 5 stages of cardiogenic shock (CS). In patients with acute myocardial infarction (AMI) who initially present in stable hemodynamic condition (SCAI CS stage: A or B), CS stages could deteriorate despite therapeutic management. However, deterioration of SCAI CS stages after AMI remains to be fully characterized.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
Cardiovascular Center, St. Luke's International Hospital, Tokyo, Japan.
Right ventricular (RV) dysfunction after biventricular repair is critical in most adults with congenital heart disease (ACHD). Conventional 2D magnetic resonance imaging (MRI) measurement is considered as a 'gold standard' for RV evaluation; however, addition information on ACHD after biventricular repair is sometimes required. The reasons why adjunctive information is required is as follows: (I) to evaluate the severity of cardiac burden in symptomatic patients with normal RV size and ejection fraction (EF), (II) to determine the optimal timing of invasive treatments in asymptomatic ones, and (III) to detect proactively a potential cardiac burden leading to ventricular deterioration, from a fluid dynamics perspective.
View Article and Find Full Text PDFJTCVS Open
December 2024
Department of Cardiovascular Surgery, Jefferson Health, Philadelphia, Pa.
Objective: To compare outcomes of aortic valve replacement (AVR) in patients with pure aortic stenosis (Pure AS) and those with pure aortic regurgitation (Pure AR) or mixed AS and AR (MAVD) in the COMMENCE trial.
Methods: Of 689 patients who underwent AVR in the COMMENCE trial, patients with moderate or severe AR with or without AS (Pure AR + MAVD; n = 135) or Pure AS (n = 323) were included. Inverse probability of treatment weighting Kaplan-Meier survival curves were used for time-to-event endpoints, and longitudinal changes in hemodynamics were evaluated using mixed-effects models.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!