Numerical modeling of specimen geometry for quantitative energy dispersive X-ray spectroscopy.

Ultramicroscopy

Department of Materials Science and Engineering, North Carolina State University, Raleigh, NC 27695, USA. Electronic address:

Published: January 2018

Transmission electron microscopy specimens typically exhibit local distortion at thin foil edges, which can influence the absorption of X-rays for quantitative energy dispersive X-ray spectroscopy (EDS). Here, we report a numerical, three-dimensional approach to model the geometry of general specimens and its influence on quantification when using single and multiple detector configurations. As a function of specimen tilt, we show that the model correctly predicts the asymmetric nature of X-ray counts and ratios. When using a single detector, we show that complex specimen geometries can introduce significant uncertainty in EDS quantification. Further, we show that this uncertainty can be largely negated by collection with multiple detectors placed symmetrically about the sample such as the FEI Super-X configuration. Based on guidance provided by the model, we propose methods to reduce quantification error introduced by the sample shape. The source code is available at https://github.com/subangstrom/superAngle.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2017.08.015DOI Listing

Publication Analysis

Top Keywords

quantitative energy
8
energy dispersive
8
dispersive x-ray
8
x-ray spectroscopy
8
numerical modeling
4
modeling specimen
4
specimen geometry
4
geometry quantitative
4
spectroscopy transmission
4
transmission electron
4

Similar Publications

Background: There is ample evidence that music can boost brain activity and jog deeply embedded memories. Literature indicates a significant improvement in autobiographical memory (ABM) recall for different individuals during background music sessions. Existing research is based solely on qualitative data, although music has a significant impact on physiological activity.

View Article and Find Full Text PDF

In-silico-based lead optimization of hit compounds targeting mitotic kinesin Eg5 for cancer management.

In Silico Pharmacol

January 2025

Phyto-medicine and Computational Biology Laboratory, Department of Biochemistry, Adekunle Ajasin University, Akungba-Akoko, Ondo State Nigeria.

Unlabelled: Lead optimization is vital for turning hit compounds into therapeutic drugs. This study builds upon a prior in silico research, where the hit compounds had better binding affinity and stability compared to a reference drug. Using a genetic algorithm, 12,500 analogs of the top compounds from the prior study were generated.

View Article and Find Full Text PDF

The pygmy sperm whale (Kogia breviceps) possesses an exocrine gland associated with its false gill slit pigmentation pattern. The cervical gill slit gland is a compound tubuloalveolar gland that produces a holocrine secretion and displays maturational changes in size and secretory histology. While the morphology of the cervical gill slit gland has been described in detail, to date, the chemical composition of its secretion remains uncharacterized.

View Article and Find Full Text PDF

Objective: In-depth investigation of the diagnostic performance of dual-energy CT (DECT) virtual non-calcium (VNCa) technique for sacroiliac joint bone marrow edema (BME) in patients with ankylosing spondylitis(AS).

Methods: A total of 42 patients with AS)who underwent sacroiliac joint MRI and DECT scans on the same day at our Rheumatology and Immunology Department between August 2022 and June 2023 were selected. Using MRI as the reference standard, the presence of BME on the iliac and sacral surfaces was evaluated, resulting in the categorization of patients into BME-positive and BME-negative groups.

View Article and Find Full Text PDF

Computational microscopy with coherent diffractive imaging and ptychography.

Nature

January 2025

Department of Physics and Astronomy, University of California, Los Angeles, Los Angeles, CA, USA.

Microscopy and crystallography are two essential experimental methodologies for advancing modern science. They complement one another, with microscopy typically relying on lenses to image the local structures of samples, and crystallography using diffraction to determine the global atomic structure of crystals. Over the past two decades, computational microscopy, encompassing coherent diffractive imaging (CDI) and ptychography, has advanced rapidly, unifying microscopy and crystallography to overcome their limitations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!