A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The law of unintended consequences: current design challenges in inferior vena cava filters. | LitMetric

Venous thromboembolic disease (VTD) encompassing deep vein thrombosis (DVT) and pulmonary embolism (PE) is a commonly encountered condition with potentially fatal sequelae. When unable to be adequately anticoagulated, patients require a mechanical means to prevent PE. This review discusses the history of inferior vena cava interruption and the development of inferior vena cava filters (IVCF). Areas covered: Milestone innovations in the mechanical treatment of VTD, their successes and shortcomings are discussed. The unforeseen complications that have occurred with implantation of IVCF have a profound impact on the present utilization of retrievable filters. Particular attention is dedicated to the evidence for safe and effective use of IVCF and the challenges presented to further improvement of these technologies. Expert commentary: While evidence suggests that IVCF are effective in preventing PE, the recent 'de-volution' from permanent to retrievable design has unleashed an epidemic device-related complications. Retrievable filter design is reliant on a 'Goldilocks' premise: make the device stable (so it doesn't migrate), but not too stable (so you can still retrieve it). Efforts must be aimed at optimizing utilization using decision support tools, meticulous follow up after deployment, and conversion from retrievable to permanent devices if the patient requires lifelong mechanical prophylaxis.

Download full-text PDF

Source
http://dx.doi.org/10.1080/17434440.2017.1374850DOI Listing

Publication Analysis

Top Keywords

inferior vena
12
vena cava
12
cava filters
8
law unintended
4
unintended consequences
4
consequences current
4
current design
4
design challenges
4
challenges inferior
4
filters venous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!