Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Use of spectroscopically-acquired spin echoes typically involves Fourier transformation of the right side of the echo while largely neglecting the left side. For sufficiently long echo times, the left side may have enough spectral resolution to offer some utility. Since the acquisition of this side is "free", we deemed it worthy of attention and investigated the spectral properties and information content of this data.
Materials And Methods: Theoretical expressions for left- and right-side spectra were derived assuming Lorentzian frequency distributions. For left-side spectra, three regimes were identified based upon the relative magnitudes of reversible and irreversible transverse relaxation rates, R ' and R , respectively. Point-resolved spectroscopy (PRESS) data from muscle, fat deposit and bone marrow were acquired at 1.5 T to test aspects of the theoretical expressions.
Results: For muscle water or methylene marrow resonances, left-side signals were substantially or moderately larger than right-side signals but were similar in magnitude for muscle choline and creatine resonances. Left- versus right-side spectral-peak amplitude ratios depend sensitively on the relative values of R and R ' , which can be estimated given this ratio and a right-side linewidth measurement.
Conclusion: Left-side spectra can be used to augment signal-to-noise and to estimate spectral R and R ' values under some circumstances.