Moisture-triggered physically transient electronics.

Sci Adv

Department of Mechanical Engineering, University of Houston, Houston, TX 77204, USA.

Published: September 2017

Physically transient electronics, a form of electronics that can physically disappear in a controllable manner, is very promising for emerging applications. Most of the transient processes reported so far only occur in aqueous solutions or biofluids, offering limited control over the triggering and degradation processes. We report novel moisture-triggered physically transient electronics, which exempt the needs of resorption solutions and can completely disappear within well-controlled time frames. The triggered transient process starts with the hydrolysis of the polyanhydride substrate in the presence of trace amounts of moisture in the air, a process that can generate products of corrosive organic acids to digest various inorganic electronic materials and components. Polyanhydride is the only example of polymer that undergoes surface erosion, a distinct feature that enables stable operation of the functional devices over a predefined time frame. Clear advantages of this novel triggered transience mode include that the lifetime of the devices can be precisely controlled by varying the moisture levels and changing the composition of the polymer substrate. The transience time scale can be tuned from days to weeks. Various transient devices, ranging from passive electronics (such as antenna, resistor, and capacitor) to active electronics (such as transistor, diodes, optoelectronics, and memories), and an integrated system as a platform demonstration have been developed to illustrate the concept and verify the feasibility of this design strategy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5580884PMC
http://dx.doi.org/10.1126/sciadv.1701222DOI Listing

Publication Analysis

Top Keywords

physically transient
12
transient electronics
12
moisture-triggered physically
8
electronics physically
8
transient
6
electronics
6
electronics form
4
form electronics
4
physically disappear
4
disappear controllable
4

Similar Publications

Background And Aims: The performance of non-invasive liver tests (NITs) is known to vary across settings and subgroups. We systematically evaluated whether the performance of three NITs in detecting advanced fibrosis in patients with metabolic dysfunction-associated steatotic liver disease (MASLD) varies with age, sex, body mass index (BMI), type 2 diabetes mellitus (T2DM) status or liver enzymes.

Methods: Data from 586 adult LITMUS Metacohort participants with histologically characterised MASLD were included.

View Article and Find Full Text PDF

Effects of exercise and transient estradiol exposure in middle-aged female rats.

Horm Behav

January 2025

Department of Psychology, University of Houston, Houston, TX 77204-5022, United States; Houston Methodist Research Institute, Houston, TX 77030, United States.

The benefits of estrogen treatment on cognition in middle-aged and older women are dependent on many factors, including the timing of treatment. Moreover, the potential interactive effects with other lifestyle factors, such as exercise, are poorly understood. In this study, we tested for lasting benefits of independent and combined treatment with estrogen and voluntary exercise initiated in midlife, using a rat model of menopause.

View Article and Find Full Text PDF

Changes in cerebrovascular reactivity as a marker of cognitive impairment risk: a transcranial Doppler study.

J Ultrasound

January 2025

Clinical Unit of Neurology, Department of Medicine, Surgery and Health Sciences, University Hospital and Health Services of Trieste, ASUGI, University of Trieste, Strada di Fiume, 447, 34149, Trieste, Italy.

Introduction: Post-stroke cognitive impairment (PSCI) and dementia affect short- and long-term outcome after stroke and can persist even after recover from a physical handicap. The process underlying PSCI is not yet fully understood. Transcranial Doppler ultrasound (TCD) is a feasible method to investigate cerebrovascular aging or dementia, through the pulsatility index (PI), the cerebrovascular reactivity (e.

View Article and Find Full Text PDF

Introduction: Patients with peripheral artery disease (PAD) can experience intermittent claudication, which limits walking capacity and the ability to undertake daily activities. While exercise therapy is an established way to improve walking capacity in people with PAD, it is not feasible in all patients. Neuromuscular electrical stimulation (NMES) provides a way to passively induce repeated muscle contractions and has been widely used as a therapy for chronic conditions that limit functional capacity.

View Article and Find Full Text PDF

Background: Radiofrequency ablation (RFA) is an emerging treatment option for small, low-risk papillary thyroid carcinoma (PTC). This systematic review and meta-analysis aimed to evaluate and compare the efficacy and safety profiles of RFA for primary T1a vs. T1b PTC.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!