Mechanical testing of femora brings valuable insights into understanding the contribution of clinically-measureable variables such as bone mineral density distribution and geometry on the femoral mechanical properties. Currently, there is no standard protocol for mechanical testing of such geometrically complex bones to measure strength, and stiffness. To address this gap we have developed a protocol to test cadaveric femora to fracture and to measure their biomechanical parameters. This protocol describes a set of adaptable fixtures to accommodate the various load magnitudes and directions accounting for possible bone orientations in a fall on the hip configuration, test speed, bone size, and left leg-right leg variations. The femora were prepared for testing by cleaning, cutting, scanning, and potting the distal end and greater trochanter contact surfaces in poly(methyl methacrylate) (PMMA) as presented in a different protocol. The prepared specimens were placed in the testing fixture in a position mimicking a sideways fall on the hip and loaded to fracture. During testing, two load cells measured vertical forces applied to the femoral head and greater trochanter, a six-axis load cell measured forces and moments at the distal femoral shaft, and a displacement sensor measured differential displacement between the femoral head and trochanter contact supports. High speed video cameras were used to synchronously record the sequence of fracture events during testing. The reduction of this data allowed us to characterize the strength, stiffness, and fracture energy for nearly 200 osteoporotic, osteopenic, and normal cadaveric femora for further development of engineering-based diagnostic tools for osteoporosis research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5614339PMC
http://dx.doi.org/10.3791/54928DOI Listing

Publication Analysis

Top Keywords

fracture testing
8
mechanical testing
8
strength stiffness
8
cadaveric femora
8
fall hip
8
greater trochanter
8
trochanter contact
8
femoral head
8
testing
7
femoral
5

Similar Publications

Background: The spinal column is a frequent site for metastases, affecting over 30% of solid tumor patients. Identifying the primary tumor is essential for guiding clinical decisions but often requires resource-intensive diagnostics.

Purpose: To develop and validate artificial intelligence (AI) models using noncontrast MRI to identify primary sites of spinal metastases, aiming to enhance diagnostic efficiency.

View Article and Find Full Text PDF

Summary: Hypophosphatasia (HPP) is a genetic disorder due to pathological variants in ALPL, the gene encoding tissue-nonspecific alkaline phosphatase (ALP). HPP is typically associated with bone-related symptoms, such as bone deformity, fractures and bone pain in children, but can appear in adults with symptoms resembling arthritis. A 22-year-old male experienced repeated and severe sudden attacks of joint pain in the elbows and knees.

View Article and Find Full Text PDF

Bioabsorbable magnesium-based bulk metallic glass composite (BMGC) for improved medial opening wedge high tibial osteotomy in knee osteoarthritis.

J Orthop Translat

January 2025

Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, 6F Biomedical Technology Building, No. 301, Yuantong Rd., Zhonghe Dist., New Taipei City, 23564, Taiwan.

Background And Objective: Osteoarthritis is a widespread and debilitating condition, particularly affecting the medial compartment of knee joint due to varus knee deformities. Medial opening wedge high tibial osteotomy (MOWHTO) has emerged as an effective treatment, but it comes with challenges like fractures, correction loss, and nonunion, leading to unsatisfactory results in up to 26 % of patients. In response, our study explores the potential of a bioabsorbable magnesium-based bulk metallic glass composite (MgZnCa BMGC) enriched with molybdenum particles as an innovative solution for MOWHTO.

View Article and Find Full Text PDF

Tumor-induced osteomalacia is characterized by hypophosphatemia and fragility fractures caused by fibroblast growth factor 23 (FGF23)-producing tumors. We report a case of tumor-induced osteomalacia in which the tumor location could be determined by gallium 68 (Ga)-DOTATOC positron emission tomography (PET)/computed tomography (CT). A 74-year-old woman had recurrent fractures and bone pain.

View Article and Find Full Text PDF

The effect of SiC and YO inclusion on microstructure and mechanical properties of Al 5052 composite fabricated through Friction Stir Process.

Heliyon

January 2025

AU-Sophisticated Testing and Instrumentation Centre (AU-STIC), CoE-Advanced Materials Synthesis (CoE-AMS), Department of Mechanical Engineering, Alliance School of Applied Engineering, Alliance University, Bengaluru, 562106, India.

A consistent research attempt to develop newer lightweight-high strength materials facilitates the automobile sector to excel in product efficiency. The present research is another endeavour to anchor the automobile industries by exploring novel composite. The different earth elements SiC and YO are utilised for the hybrid reinforcement of Al 5052 alloy in four different weight proportions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!