Background/aim: To assess the clinical impact of high dose rate stereotactic body radiation therapy (SBRT) in patients with lung neoplastic lesions.

Patients And Methods: From January 2014 to June 2016, a single-center retrospective analysis was performed including all patients treated by either flattening filter free (FFF) beams or flattening filter beams (FF) three-dimensional (3D) SBRT for lung neoplastic lesions.

Results: A total of 99 SBRT were performed on 75 patients. Among these, 29 SBRT were performed using a FFF technique while 70 other SBRT were done using a FF technique. Median follow-up time was 12.9 months. Overall, no difference between the two groups was found except for the mean beam on time which was reduced by 3.3 to 0.9 minutes in the FFF group (p<0.001).

Conclusion: We report a low toxicity rate and a shortened beam on time in patients treated with 3D FFF SBRT for lung neoplastic lesions.

Download full-text PDF

Source
http://dx.doi.org/10.21873/anticanres.11933DOI Listing

Publication Analysis

Top Keywords

flattening filter
12
filter free
8
stereotactic body
8
body radiation
8
radiation therapy
8
lung neoplastic
8
sbrt performed
8
sbrt
5
free flattened
4
flattened beams
4

Similar Publications

Background: Stereotactic arrythmia radioablation (STAR) is a noninvasive technique to treat ventricular tachycardia (VT). Management of cardiorespiratory motion plays an essential role in VT-STAR treatments to improve treatment outcomes by reducing positional uncertainties and increasing dose conformality. Use of an electrocardiogram (ECG) signal, acquired in real-time, as a surrogate to gate the beam has the potential to fulfil that intent.

View Article and Find Full Text PDF

Background: The clinical use of flattening filter free (FFF) radiotherapy has significantly increased in recent years due to its effective enhancement of dose rates and reduction of scatter dose. A proposal has been made to adjust the incident electron angle of the accelerator to expand the application of FFF beams in areas such as large planning target volumes (PTVs). However, the inherent softening characteristics and non-uniformity of lateral dose distribution in FFF beams inevitably lead to increased dosimetry errors, especially for ionization chambers widely used in clinical practice, which may result in serious accidents during FFF radiotherapy.

View Article and Find Full Text PDF

Parallel generation of multi-channel chaos is critical to applications, and the key challenge is the simultaneous generation of broadband chaos with multiple channels and low correlation. Here, we experimentally demonstrate a parallel broadband chaos generation scheme using a single long-active-cavity Fabry-Perot (LC-FP) semiconductor laser under optical feedback. The active-cavity length is designed to be 1500 μm, so the power spectrum of chaos is expanded and flattened by the mode-beating effect.

View Article and Find Full Text PDF

Prosodic Preferences of Surface Electromyography-based Subvocal Speech for People With Laryngectomy.

J Voice

December 2024

Delsys, Inc., Natick, Massachusetts 01760; Altec, Inc., Natick, Massachusetts 01760; Department of Speech, Language and Hearing Sciences, Boston University, Boston, Massachusetts 02215. Electronic address:

Introduction: People who undergo a total laryngectomy lose their natural voice and depend on alaryngeal technologies for communication. However, these technologies are often difficult to use and lack prosody. Surface electromyographic-based silent speech interfaces are novel communication systems that overcome many of the shortcomings of traditional alaryngeal speech and have the potential to seamlessly incorporate individualized prosody.

View Article and Find Full Text PDF

Space division multiplexing (SDM) systems using few-mode fibers (FMF) are essential for next-generation fiber optic communications. Optical amplifiers with low noise, minimal differential modal gain (DMG), and minimal differential spectral gain (DSG) are essential for these systems. In this work, we present a method to design and optimize a two-stage few-mode erbium-doped fiber amplifier (FM-EDFA) using a joint DMG-DSG minimization approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!