A centrifugal pump with a unique structure has been developed for chronic support. The pump is driven by a magnetic coupling and has no rotating shaft, no seal around the rotating part, and a balancing hole at the center of the impeller and the thrust bearing. The pump was improved in stepwise fashion to realize good antithrombogenicity and low hemolysis. The first pump, the National Cardiovascular Center (NCVC)-O, had an impeller with 4 rectangular and curved vanes; 6 triangularly shaped curved vanes were employed in the second model, the NCVC-1, to reduce trauma to the blood. In the third design, the NCVC-2, the central hole was enlarged, and the thrust bearing shoulder was rounded so that blood washing was enhanced around the impeller; stream lines also were smoothed for improved antithrombogenicity. The hemolytic property of the device was evaluated in vitro with heparinized fresh goat blood; hemolysis indexes of the NCVC-0, -1, and -2 were 0.05, 0.01, and 0.006 g per 100 L, respectively. Antithrombogenicity of the pumps was examined in animal experiments as a left heart bypass device in goats weighing 52-75 kg. Six NCVC-0 pumps were driven for 14 to 33 (22.0 ± 7.6) days in goats receiving the antiplatelet drug cilostazol orally. Four NCVC-I pumps ran for 1 to 80 (28.5 ± 30.6) days with the same drug regimen in 2 cases and with no anticoagulation therapy in 2 cases. After 3 preliminary 1-week tests of NCVC-2 pumps in animals, the pump was installed in 3 goats; 2 pumps were still running on the 182nd and 58th pumping day. Intracorporeal implantation also was attempted successfully. The results indicate that this pump has promising features for chronic support although longer term and additional evaluations are necessary.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1525-1594.1996.tb04470.x | DOI Listing |
Int Heart J
December 2024
Department of Cardiovascular Surgery, The Second Hospital of Jilin University.
This study aimed to summarize our experience using a systematic approach to reduce blood transfusions in acute type A aortic dissection (ATAAD) surgery.From August 2016 to June 2020, 326 patients underwent ATAAD surgery in our center employing a systematic approach, which primarily included the following: Liu's aortic root repair technique, Liu's aortic arch inclusion technique with a frozen elephant trunk, moderate-to-mild hypothermia circulatory arrest, and application of centrifugal pump in cardiopulmonary bypass circuit. Patients were divided into two groups based on whether they had blood product transfusion during their hospital stay: transfusion group and transfusion-free group.
View Article and Find Full Text PDFNutrients
November 2024
Department of Pediatrics and Human Development, College of Human Medicine, Michigan State University, Grand Rapids, MI 49503, USA.
Background/objectives: Multiple independent variables were analyzed to determine total nutritional intake (caloric and protein), while reviewing vasoactive inotrope scores (VISs).
Methods: Retrospective data were collected for nutritional intake (N = 64), daily VISs, extracorporeal membrane oxygenation (ECMO) complications, delays in nutritional intake (>48 h), reason for delay, and interruptions in nutrition support.
Results: VISs and ECMO characteristics analyzed by box-whisker plots demonstrated that ECMO complications prior to 24 h, cardiac arrest 24 h prior to ECMO, pediatric ECMO patients, venoarterial ECMO type, having a cardiac ECMO indication, and ECMO centrifugal pump had higher VISs.
Bioengineering (Basel)
November 2024
Biomedical Research Center, Qatar University, Doha 2713, Qatar.
A comprehensive analysis of in vitro pumps used in cardiovascular research is provided in this review, with a focus on the characteristics of generated flows and principles of flow generations. The cardiovascular system, vital for nutrient circulation and waste removal, generates complex hemodynamics critical for endothelial cell function. Cardiovascular diseases (CVDs) could be caused by the disturbances in these flows, including aneurysms, atherosclerosis, and heart defects.
View Article and Find Full Text PDFArtif Organs
November 2024
Department of Cardiovascular and Thoracic Surgery, Institute of Cardiology, Pitié Salpêtrière Hospital, Assistance Publique Hôpitaux de Paris (AP-HP), Sorbonne University, Paris, France.
Background: An innovative solution has been recently proposed for the treatment of heart failure with preserved ejection fraction (HFpEF), using a centrifugal mechanical circulatory support (MCS) device. We sought firstly to assess the hemocompatibility of the proposed device. HFpEF treatment requires the blood pump to operate at low blood flow rate (0.
View Article and Find Full Text PDFJ Biomech Eng
February 2025
Arts et Métiers Institute of Technology, CNAM, LIFSE, Paris F-75013, France.
Blood pumps, critical components in ventricular assist devices and extracorporeal membrane oxygenation systems, are primarily evaluated based on their ability to minimize blood damage through optimized design. Despite extensive research, the impact of impeller blade thickness and the proximity of rotating and stationary surfaces remains insufficiently explored. This study presents a comprehensive analysis, combining experimentally validated numerical simulations with an advanced Lagrangian approach, to compare the hemodynamic and hemolytic performance of three centrifugal pumps.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!