Purpose: To implement and evaluate interleaved blip-up, blip-down, non-segmented 3D echo planar imaging (EPI) with pseudo-continuous arterial spin labeling (pCASL) and post-processing for reduced susceptibility artifact cerebral blood flow (CBF) maps.

Materials And Methods: 3D EPI non-segmented acquisition with a pCASL labeling sequence was modified to include alternating k-space coverage along phase encoding direction (referred to as "blip-reversed") for alternating dynamic acquisitions of control and label pairs. Eight volunteers were imaged on a 3T scanner. Images were corrected for distortion using spatial shifting transformation of the underlying field map. CBF maps were calculated and compared with maps obtained without blip reversal using matching gray matter (GM) images from a high resolution 3D scan. Additional benefit of using the correction for alternating blip-up and blip-down acquisitions was assessed by comparing to corrected blip-up only and corrected blip-down only CBF maps. Matched Student t-test of overlapping voxels for the eight volunteers was done to ascertain statistical improvement in distortion.

Results: Mean CBF value in GM for the eight volunteers from distortion corrected CBF maps was 50.8±9.9ml/min/100 gm tissue. Corrected CBF maps had 6.3% and 4.1% more voxels in GM when compared with uncorrected blip up (BU) and blip down (BD) images, respectively. Student t-test showed significant reduction in distortion when compared with blip-up images and blip-down images (p<0.001). When compared with corrected BU and corrected BD only CBF maps, BU and BD corrected maps had 2.3% and 1% more voxels (p=0.006 and 0.04, respectively).

Conclusion: Pseudo-continuous arterial spin labeling with non-segmented 3D EPI acquisition using alternating blip-reversed k-space traversal and distortion correction provided significantly better matching GM CBF maps. In addition, employing alternating blip-reversed acquisitions during pCASL acquisition resulted in statistically significant improvement over corrected blip-up and blip-down CBF maps.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5885766PMC
http://dx.doi.org/10.1016/j.mri.2017.08.011DOI Listing

Publication Analysis

Top Keywords

cbf maps
16
non-segmented echo
8
echo planar
8
planar imaging
8
pseudo-continuous arterial
8
arterial spin
8
spin labeling
8
blip-up blip-down
8
student t-test
8
corrected cbf
8

Similar Publications

Proteomic Insights into the Regulatory Mechanisms of the Freezing Response in the Alpine Subnivale Plant .

Int J Mol Sci

December 2024

Ministry of Education Key Laboratory of Cell Activities and Stress Adaptations, School of Life Sciences, Lanzhou University, Lanzhou 730000, China.

Freezing temperatures impose significant constraints on plant growth and productivity. While cold tolerance mechanisms have been extensively studied in model species, the molecular basis of freezing tolerance in naturally adapted plants remains underexplored. , an alpine plant with a strong freezing tolerance, provides a valuable model for investigating these adaptive mechanisms.

View Article and Find Full Text PDF

This study aimed to investigate the impact of selected analysis conditions on blood flow values and color maps in canine brain perfusion computed tomography (PCT) and to propose optimal analysis conditions. Dynamic computed tomography imaging was performed on six beagle dogs. Color maps were generated using a combination of analysis algorithms (box-modulation transfer function (Box-MTF) and singular value deconvolution plus (SVD+) methods), slice thicknesses (4.

View Article and Find Full Text PDF

Purpose: To investigate the clinical feasibility of a CT collateral map compared with an MRA collateral map, focusing on collateral perfusion (CP) estimation and baseline lesion assessment in acute ischemic stroke (AIS).

Materials And Methods: This retrospective analysis used selected data from a prospectively collected database. We generated CT collateral maps derived from CT perfusion, encompassing images of arterial, capillary, early venous (CMEV), late venous, and delay phases.

View Article and Find Full Text PDF

Dynamic B field shimming for improving pseudo-continuous arterial spin labeling at 7 T.

Magn Reson Med

December 2024

Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.

Purpose: B field inhomogeneity within the brain-feeding arteries is a major issue for pseudo-continuous arterial spin labeling (PCASL) at 7 T because it reduces the labeling efficiency and leads to a loss of perfusion signal. This study aimed to develop a vessel-specific dynamic B field shimming method for 7 T PCASL to improve the labeling efficiency by correcting off-resonance within the arteries in the labeling region.

Methods: We implemented a PCASL sequence with dynamic B shimming at 7 T that compensates for B field offsets in the brain-feeding arteries by updating linear shimming terms and adding a phase increment to the PCASL RF pulses.

View Article and Find Full Text PDF

A Novel Self-Supervised Learning-Based Method for Dynamic CT Brain Perfusion Imaging.

J Imaging Inform Med

December 2024

Institute of Medical Device and Imaging, College of Medicine, Zhongzheng Dist, National Taiwan University, No.1, Sec. 1, Jen Ai Rd, Taipei City, 100, Taiwan.

Dynamic computed tomography (CT)-based brain perfusion imaging is a non-invasive technique that can provide quantitative measurements of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). However, due to high radiation dose, dynamic CT scan with a low tube voltage and current protocol is commonly used. Because of this reason, the increased noise degrades the quality and reliability of perfusion maps.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!