A new dataset of cosmetics-related chemicals for the Threshold of Toxicological Concern (TTC) approach has been compiled, comprising 552 chemicals with 219, 40, and 293 chemicals in Cramer Classes I, II, and III, respectively. Data were integrated and curated to create a database of No-/Lowest-Observed-Adverse-Effect Level (NOAEL/LOAEL) values, from which the final COSMOS TTC dataset was developed. Criteria for study inclusion and NOAEL decisions were defined, and rigorous quality control was performed for study details and assignment of Cramer classes. From the final COSMOS TTC dataset, human exposure thresholds of 42 and 7.9 μg/kg-bw/day were derived for Cramer Classes I and III, respectively. The size of Cramer Class II was insufficient for derivation of a TTC value. The COSMOS TTC dataset was then federated with the dataset of Munro and colleagues, previously published in 1996, after updating the latter using the quality control processes for this project. This federated dataset expands the chemical space and provides more robust thresholds. The 966 substances in the federated database comprise 245, 49 and 672 chemicals in Cramer Classes I, II and III, respectively. The corresponding TTC values of 46, 6.2 and 2.3 μg/kg-bw/day are broadly similar to those of the original Munro dataset.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fct.2017.08.043DOI Listing

Publication Analysis

Top Keywords

cramer classes
16
classes iii
12
cosmos ttc
12
ttc dataset
12
toxicological concern
8
chemical space
8
chemicals cramer
8
final cosmos
8
quality control
8
federated dataset
8

Similar Publications

Optimizing quantitative photoacoustic imaging systems: the Bayesian Cramér-Rao bound approach.

Inverse Probl

December 2024

Oden Institute for Computational Engineering and Sciences, The University of Texas, Austin, TX 78712, United States of America.

Article Synopsis
  • qPACT is an advanced medical imaging technique that aims to provide detailed images of important physiological metrics like hemoglobin levels and oxygen saturation, but its image reconstruction involves complex, non-linear mathematical challenges.
  • There is currently no standardized design for qPACT systems, leading to uncertainty about which system designs are optimal for different medical applications.
  • This research introduces a new computational method for optimizing the design of qPACT systems using the Bayesian Cramér-Rao bound, demonstrating its effectiveness through numerical simulations, marking a significant advancement in the field of imaging governed by partial differential equations.
View Article and Find Full Text PDF
Article Synopsis
  • * Factors such as higher education and income were linked to better PROMs, while specific brain injuries affected performance ratings differently, highlighting the impact of socioeconomics and brain health on recovery perceptions.
  • * The research identified a connection between parietal lobe damage and poorer self-reported outcomes, suggesting that injuries affecting self-awareness can distort patients' assessments of their own capabilities.
View Article and Find Full Text PDF

The existing information supports the use of this material as described in this safety assessment. 4-(4-Methyl-3-penten-1-yl)-2(5H)-furanone was evaluated for genotoxicity, repeated dose toxicity, reproductive toxicity, local respiratory toxicity, photoirritation/photoallergenicity, skin sensitization, and environmental safety. Data show that 4-(4-methyl-3-penten-1-yl)-2(5H)-furanone is not mutagenic.

View Article and Find Full Text PDF

The Cramer classification scheme has emerged as one of the most extensively-adopted predictive toxicology tools, owing in part to its employment for chemical categorisation within threshold of toxicological concern evaluation. The characteristics of several of its rules have contributed to inconsistencies with respect to degree of hazard attributed to common (particularly food-relevant) substances. This investigation examines these discrepancies, and their origins, raising awareness of such issues amongst users seeking to apply and/or adapt the rule-set.

View Article and Find Full Text PDF

Generative AI with WGAN-GP for boosting seizure detection accuracy.

Front Artif Intell

October 2024

Applied Artificial Intelligence Institute (I2A), TELUQ University, Montreal, QC, Canada.

Background: Imbalanced datasets pose challenges for developing accurate seizure detection systems based on electroencephalogram (EEG) data. Generative AI techniques may help augment minority class data to facilitate automatic epileptic seizure detection.

New Method: This study investigates the impact of various data augmentation (DA) approaches, including Wasserstein Generative Adversarial Network with Gradient Penalty (WGAN-GP), Vanilla GAN, Conditional GAN (CGAN), and Cramer GAN, on classification performance with Random Forest models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!