A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Longitudinal dialysis adequacy and clinical performance of the VectorFlow hemodialysis catheter: a prospective study. | LitMetric

Purpose: To report clinical performance and longitudinal assessment of hemodialysis adequacy with the Arrow-Clark VectorFlow catheter, a symmetrical-tip device with a distal lumen configuration designed to reduce platelet shear stress and catheter thrombosis.

Methods And Materials: We prospectively enrolled patients who required de novo placement of a chronic tunneled catheter for hemodialysis or exchange of a dysfunctional catheter as part of an Institutional Review Board (IRB)-approved protocol. Catheter patency, Kt/V, mean blood-flow (Qb), and pump pressures were obtained at baseline and at monthly intervals to 90 days.

Results: Forty-six subjects were enrolled into the study. During the 90-day observation period, maximum blood-flow rate averaged 355-398 mL/minute; mean Qb averaged 333-392 mL/minute. Mean Kt/V values were consistently ≥1.5. Dwell-time was 15-114 days, for a total of 2997 catheter days (mean 71.4 days). Excluding patients who died during the study and those receiving surgical access, overall intervention-free catheter patency rate was 94.9%, 92.2% and 88.8% at days 30, 60, 90, respectively. There were no acute complications. During the follow-up period, three patients developed complications (6.5%). Two catheter infections occurred (0.7/1000 catheter days) and one catheter malfunctioned; a rate of 1.0/ 1000 catheter days for all complications.

Conclusions: The VectorFlow catheter produced safe, effective hemodialysis with Kt/V ≥1.5. A single catheter occlusion occurred and a low rate of infection was seen. Results support the hypothesis that the VectorFlow design reduces thrombogenic risk during clinical performance.

Download full-text PDF

Source
http://dx.doi.org/10.5301/jva.5000784DOI Listing

Publication Analysis

Top Keywords

catheter
14
clinical performance
12
catheter days
12
vectorflow catheter
8
catheter patency
8
days
6
longitudinal dialysis
4
dialysis adequacy
4
adequacy clinical
4
vectorflow
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!