A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Use of de novo sequencing for proteins identification]. | LitMetric

Three de novo sequencing programs (Novor, PEAKS and PepNovo+) have been used for identification of 48 individual human proteins constituting the Universal Proteomics Standard Set 2 (UPS2) ("Sigma-Aldrich", USA). Experimental data have been obtained by tandem mass spectrometry. The MS/MS was performed using pure UPS2 and UPS2 mixtures with E. coli extract and human plasma samples. Protein detection was based on identification of at least two peptides of 9 residues in length or one peptide containing at least 13 residues. Using these criteria 13 (Novor), 20 (PEAKS) and 11 (PepNovo+) proteins were detected in pure UPS2 sample. Protein identifications in mixed samples were comparable or worse. Better results (by ~20%) were obtained using prediction included high quality identified fragment (TAG) containing at least 7 residues and unidentified additional masses at N- and C-termini (PepNovo+). The latter approach confidently recognized mass-spectrometric artefacts (and probably PTM). Atypical mass changes missed in UNIMOD DB were found (PepNovo+) to be statistically significant at the C-terminus (+23.02, +26.04 and +27.03). Using peptides containing these modifications and milder detection threshold 41 of 48 UPS2 proteins were identified.

Download full-text PDF

Source
http://dx.doi.org/10.18097/PBMC20176304341DOI Listing

Publication Analysis

Top Keywords

novo sequencing
8
novor peaks
8
peaks pepnovo+
8
pure ups2
8
ups2
5
[use novo
4
proteins
4
sequencing proteins
4
proteins identification]
4
identification] three
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!