Evaluation of noise hazard during the holmium laser enucleation of prostate.

BMC Urol

Department of Urology, Shanghai 9th People's Hospital, Shanghai Jiaotong University School of Medicine, 639 Zhi Zaoju Road, Shanghai, 200011, China.

Published: August 2017

Background: To evaluate noise hazard during holmium laser enucleation of the prostate (HoLEP), we designed a study to detect such a risk in this procedure.

Methods: This study was conducted over a 12-month period on 223 patients with benign prostatic hyperplasia (BPH), 121 of whom underwent HoLEP while those remaining underwent transurethral resection of the prostate (TURP). A sound level meter was used to detect the exposure of surgeons to noise. The recordings used were in accordance with the standards set by the Occupational Safety and Health Administration (OSHA) and the United States E nvironmental Protection A gency . Moreover, each of the 43 surgeons participating in a BPH discussion conference answered the questionnaire on the influence of noise, and 33 surgeons in our department volunteered for blood pressure monitoring post-surgically.

Results: The sound level produced by a high-powered holmium laser emitter during HoLEP was 67.37 ± 0.13 dB, which was significantly higher than the sound heard during TURP (46.41 ± 0.29 dB, P < 0.01). The 65-70 dB noise during HoLEP was proved to be a safe level in accordance with the OSHA standards. However, this level was considerably greater than the stated 55 dB. Moreover, it exceeded the normal communication protective level of 60 dB. In the analysis of responses from the surgeons, the HoLEP group obtained an average score that reflected disturbance caused by the laser emitter and an increase in average systolic pressure relative to that in the TURP group.

Conclusions: The noise level during HoLEP is within hearing conservation levels. However, the noise disturbs intrateam communication and concentration during surgery. Some surgeons may experience discomfort post-surgically, but no significant difference among the groups is indicated. The findings suggest that measures should be taken to address the noise caused by the laser emitter during HoLEP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5577658PMC
http://dx.doi.org/10.1186/s12894-017-0246-yDOI Listing

Publication Analysis

Top Keywords

holmium laser
12
noise hazard
8
hazard holmium
8
laser enucleation
8
enucleation prostate
8
sound level
8
evaluation noise
4
prostate background
4
background evaluate
4
evaluate noise
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!