A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ): Dynamic myocardial T mapping using a cine steady-state look-locker approach. | LitMetric

Purpose: To develop and evaluate a cardiac phase-resolved myocardial T mapping sequence.

Methods: The proposed method for temporally resolved parametric assessment of Z-magnetization recovery (TOPAZ) is based on contiguous fast low-angle shot imaging readout after magnetization inversion from the pulsed steady state. Thereby, segmented k-space data are acquired over multiple heartbeats, before reaching steady state. This results in sampling of the inversion-recovery curve for each heart phase at multiple points separated by an R-R interval. Joint T and B1+ estimation is performed for reconstruction of cardiac phase-resolved T and B1+ maps. Sequence parameters are optimized using numerical simulations. Phantom and in vivo imaging are performed to compare the proposed sequence to a spin-echo reference and saturation pulse prepared heart rate-independent inversion-recovery (SAPPHIRE) T mapping sequence in terms of accuracy and precision.

Results: In phantom, TOPAZ T values with integrated B1+ correction are in good agreement with spin-echo T values (normalized root mean square error = 4.2%) and consistent across the cardiac cycle (coefficient of variation = 1.4 ± 0.78%) and different heart rates (coefficient of variation = 1.2 ± 1.9%). In vivo imaging shows no significant difference in TOPAZ T times between the cardiac phases (analysis of variance: P = 0.14, coefficient of variation = 3.2 ± 0.8%), but underestimation compared with SAPPHIRE (T time ± precision: 1431 ± 56 ms versus 1569 ± 65 ms). In vivo precision is comparable to SAPPHIRE T mapping until middiastole (P > 0.07), but deteriorates in the later phases.

Conclusions: The proposed sequence allows cardiac phase-resolved T mapping with integrated B1+ assessment at a temporal resolution of 40 ms. Magn Reson Med 79:2087-2100, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5811329PMC
http://dx.doi.org/10.1002/mrm.26887DOI Listing

Publication Analysis

Top Keywords

cardiac phase-resolved
12
temporally resolved
8
resolved parametric
8
parametric assessment
8
assessment z-magnetization
8
z-magnetization recovery
8
recovery topaz
8
myocardial mapping
8
steady state
8
vivo imaging
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!