High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5560838 | PMC |
http://dx.doi.org/10.1364/BOE.8.003749 | DOI Listing |
Eur Heart J Acute Cardiovasc Care
January 2025
Department of Heart Disease, Haukeland University Hospital, Bergen, Norway.
Background: This prospective, two-centre study derived and validated predictive algorithms for the Siemens Atellica IM high-sensitivity cardiac troponin I (hs-cTnI) assay in the emergency department (ED).
Methods: Algorithms for predicting 30-day myocardial infarction type 1 and 2 (MI) and death or non-ST-elevation myocardial infarction (NSTEMI, type 1 and 2) at index admission were developed from a derivation cohort of 1896 patients and validated using a synthetic dataset with nearly 1 million patient cases. Performance was compared to the European Society of Cardiology algorithms for hs-cTnT (Roche Diagnostics) and hs-cTnI (Abbott Diagnostics).
Front Cardiovasc Med
January 2025
Department of Cardiology, Joan XXIII University Hospital, Tarragona, Spain.
Introduction: Cardiac troponin levels below the 99th percentile improve the predictive efficacy for cardiovascular events when associated with relevant clinical variables. However, whether ultra-sensitive analytical methods improve this predictive efficacy over less sensitive or contemporary analytical methods remains unknown.
Methods: This retrospective observational study involved consecutive patients who presented to the emergency department for suspected acute coronary syndrome and underwent measurement of ultra-sensitive cardiac troponin I (Singulex) and contemporary cardiac troponin I (Siemens) with levels below the 99th percentile.
Open Access Emerg Med
January 2025
Nuclear Medicine Department, Center of Nuclear Medicine and Oncology, Semey, Abay Region, Kazakhstan.
Background: One of the most serious complications of coronary artery stenting is restenosis and in-stent thrombosis; their prevalence can reach 20-25%. Stent thrombosis can be acute (up to 24 hours), subacute (24 hours to 30 days), late (30 days to 1 year), and very late (> 1 year after previous stenting). In the patients with COVID-19 in intensive care units, the proportion of those with elevated troponin levels reached 25%.
View Article and Find Full Text PDFJ Agric Food Chem
January 2025
Guizhou Key Laboratory of New Quality Processing and Storage of Ecological Specialty Food; School of Liquor and Food Engineering, Guizhou University, Guiyang 550025, China.
Traditional dry-curing methods have a long cycle time and low efficiency, resulting in the inconsistent quality of dry-cured ham. By applying electrical stimulation (ES) technology in the dry-curing process, it was found that ES affected mitochondrial apoptosis by modulating the intracellular environment of muscle cells, which, in turn, enhanced the quality of dry-cured pork loin. Specifically, ES accelerated glycogen and ATP depletion, which led to a rapid decline in pH.
View Article and Find Full Text PDFAm Heart J Plus
January 2025
Department of Emergency Medicine, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
Background: Identifying and eliminating health disparities is a public health priority. The goal of this analysis is to determine whether cardiac testing or outcome disparities exist by race or sex in patients with detectable to mildly elevated serum troponin.
Methods: We conducted a secondary analysis of the CMR-IMPACT trial that randomized patients with symptoms suggestive of acute coronary syndrome and a detectable or mildly elevated troponin measure from 4 US hospitals to an early invasive angiography or cardiac MRI strategy.