The emergence of fluorescently labeled therapeutic antibodies has given rise to molecular probes for image-guided surgery. However, the extraneous interstitial presence of an unbound and nonspecifically accumulated probe gives rise to false-positive detection of tumor tissue and margins. Thus, the concept of tumor-cell activation of smart probes provides a potentially superior mechanism of delineating tumor margins as well as small tumor deposits. The combination of molecular targeting with intracellular activation circumvents the presence of extracellular, nonspecific signals of targeted probe accumulation. Here, we present a demonstration of the clinical antibodies cetuximab (cet, anti-EGFR mAb) and trastuzumab (trast, anti-HER-2 mAb) conjugated to Alexa Fluor molecules and IRDye QC-1 quencher optimized at the ratio of 1∶2∶6 to provide the greatest degree of proteolytic fluorescence activation, synonymous with intracellular lysosomal degradation. The cet-AF-Q-C1 conjugate (1∶2∶6) provides up to 9.8-fold proteolytic fluorescence activation. By preparing a spectrally distinct, irrelevant sham IgG-AF-QC-1 conjugate, a dual-activatable probe approach is shown to enhance the specificity of imaging within an orthotopic AsPC-1 pancreatic cancer xenograft model. The dual-activatable approach warrants expedited clinical translation to improve the specificity of image-guided surgery by spectrally decomposing specific from nonspecific probe accumulation, binding, and internalization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5574035PMC
http://dx.doi.org/10.1117/1.JBO.22.12.121607DOI Listing

Publication Analysis

Top Keywords

image-guided surgery
12
molecular probes
8
specificity image-guided
8
probe accumulation
8
proteolytic fluorescence
8
fluorescence activation
8
activatable clinical
4
clinical fluorophore-quencher
4
fluorophore-quencher antibody
4
antibody pairs
4

Similar Publications

Implementation Strategies and Ergonomic Factors in Robot-assisted Microsurgery.

J Robot Surg

January 2025

BG Trauma Center Ludwigshafen, Department for Plastic, Hand and Reconstructive Surgery, Department of Plastic Surgery for the Heidelberg University, Ludwig-Guttmann-Straße 13, 67071, Ludwigshafen, Germany.

Robot-assisted surgery represents a significant innovation in reconstructive microsurgery, providing enhanced precision and reduced surgeon fatigue. This study examines the integration of robotic assistance in a series of 85 consecutive robot-assisted microsurgical (RAMS) operations. It aims to evaluate changes in the integration of RAMS during the implementation phase in a single institution.

View Article and Find Full Text PDF

Safety and clinical efficacy of modified tracer fixation technique in orthopedic robot-assisted percutaneous vertebroplasty for Kümmell's disease.

J Robot Surg

January 2025

Department of Orthopaedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210028, Jiangsu, China.

The rising incidence of osteoporotic vertebral compression fractures (OVCF) has increased the demand for precise treatments like robot-assisted percutaneous vertebroplasty (PVP), especially for conditions like Kümmell's disease that require high surgical accuracy. However, the traditional tracer fixation method has certain limitations. This study aimed to compare the safety and clinical efficacy of a modified tracer fixation technique with the traditional fixation method in robot-assisted percutaneous vertebroplasty (PVP) for Kümmell's disease.

View Article and Find Full Text PDF

Robotic sugarbaker parastomal hernia repair: updated series and outcomes.

Hernia

January 2025

Division of Gastrointestinal and Minimally Invasive Surgery, Department of Surgery, Carolinas Medical Center, 1025 Morehead Medical Drive Suite 300, Charlotte, NC, 28204, USA.

Purpose: To present updated outcomes after previously describing a novel technique for the robotic repair of parastomal hernias.

Methods: Patients who underwent parastomal hernia repair with a robotic Sugarbaker technique at a tertiary hernia center were identified from an institutional database. The approach involves mesh placement in the intraperitoneal or preperitoneal position after closure of the fascial defect.

View Article and Find Full Text PDF

Accuracy of robot-assisted implant surgery versus freehand placement: a retrospective clinical study.

Int J Implant Dent

January 2025

Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China.

Purpose: This study evaluated the accuracy of implant placement using a robotic system (Remebot) compared to freehand surgery and explored factors influencing accuracy.

Methods: This retrospective study included 95 implants placed in 65 patients, divided into robot-assisted (50 implants) and freehand (45 implants) groups. Platform, apical, and angular deviations were measured by superimposing preoperative plans and the postoperative CBCT images.

View Article and Find Full Text PDF

Obesity presents a significant public health challenge, known to escalate the risk of colorectal cancer twofold. The potential advantages of employing robotic technology in colorectal surgery for obese individuals remain mostly unexplored. A comprehensive search of articles retrieved from Scopus, PubMed, and the Cochrane Library for the duration of January 2014 to March 2024 was performed, without language limitations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!