Introduction: Kilovoltge cone beam computed tomography (kV-CBCT) allows for tumor localization and response assessment during definitive chemoradiotherapy for locally advanced NSCLC. We hypothesize that significant tumor volume loss occurs early during radiotherapy and that the extent of volume loss correlates with clinical outcomes.
Methods: A total of 52 patients with locally advanced NSCLC treated with definitive chemoradiotherapy were reviewed. kV-CBCT images were used to contour primary gross tumor volumes at four time points during treatment. Patients were dichotomized according to absolute and relative volume changes at each time point. Statistical analyses were performed to evaluate correlations between volume changes and clinical outcomes.
Results: The median gross tumor volumes were 77.1, 48.3, 42.5, and 29.9 cm for fractions 1, 11, 21, and final, respectively. Greater relative volume loss between fractions 1 and 21 correlated with improved distant control (hazard ratio [HR] = 0.35, 95% confidence interval [CI]: 0.13-0.94, p = 0.038) and overall survival (HR = 0.40, 95% CI: 0.16-0.98, p = 0.046). Greater relative volume loss between fractions 11 and 21 correlated with improved progression-free survival (HR = 0.39, 95% CI: 0.17-0.88, p = 0.02) and trended toward improved overall survival (HR = 0.43, 95% CI: 0.17-1.06, p = 0.07). On multivariate analysis, greater relative volume loss between fractions 11 and 21 correlated with improved progression-free survival (HR = 0.39, 95% CI: 0.16-0.97, p = 0.041) and overall survival (HR = 0.31, 95% CI: 0.11-0.88, p = 0.027).
Conclusions: Significant primary tumor volume loss occurs early during radiotherapy for locally advanced NSCLC. Greater relative tumor volume loss during treatment correlates with improved disease control and overall survival. Thus, kV-CBCT has potential to be used as a practical prognostic imaging marker.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jtho.2017.08.010 | DOI Listing |
Muscle Nerve
January 2025
Division of Neurology, Department of Medicine, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
Introduction/aims: Spirometry is the conventional means to measure lung function in amyotrophic lateral sclerosis (ALS), but is dependent on patient effort and bulbar strength. We aimed to use electric impedance tomography (EIT), an emerging non-invasive imaging modality, to measure dynamic lung volume changes.
Methods: Twenty-one patients with ALS underwent sitting and supine spirometry for forced vital capacity (FVC), and sitting and supine EIT.
Int J Gynaecol Obstet
January 2025
Effective Care Research Unit, University of the Witwatersrand and Walter Sisulu University, East London, South Africa.
Objective: To compare low-cost "Suction Tube Uterine Tamponade" (STUT) treatment for refractory postpartum hemorrhage (PPH) with uterine balloon tamponade (UBT) using a randomized feasibility study.
Methods: After verbal assent, we allocated participants with refractory PPH by randomly ordered envelopes to STUT or routine UBT at 10 hospitals in South Africa and one tertiary referral center in Colombia between January 10, 2020, and May 3, 2024. In the STUT group, we inserted a 24 FG Levin stomach tube into the uterine cavity and applied suction.
J Funct Biomater
December 2024
Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University, Nagoya 464-8651, Japan.
The purpose of this study was to compare the wear resistance of light-cure resin luting cements for veneers with that of other luting materials investigated in earlier studies. An Alabama wear-testing machine was used to measure the wear resistance of four recent light-cure resin luting cements for veneers (G-Cem Veneer; Panavia V5 LC; RelyX Veneer Cement; and Vario-link Esthetic LC). The volume loss ranged from 0.
View Article and Find Full Text PDFMembranes (Basel)
January 2025
Nephrology and Renal Transplantation, Hospital Clínic de Barcelona, 08036 Barcelona, Spain.
The dialysis membrane based on a hydrophilic polymer (Hydrolink NV) was designed to enhance the movement of adsorbed water at the blood-membrane interface, aiming to achieve antithrombogenic and antifouling effects. This study aimed to assess the performance and albumin loss of the Hydrolink NV dialyzer in hemodialysis (HD) and post-dilution hemodiafiltration (HDF) with different infusion flows (Qis) and compare it with the hydrophilic FX CorAL dialyzer in post-dilution HDF. A prospective study was carried out in 20 patients.
View Article and Find Full Text PDFArthroplast Today
February 2025
Department of Orthopedic Surgery, University of California, Los Angeles, Santa Monica, CA, USA.
Background: Revision hip and knee arthroplasty volume continues to rise, and total femur replacement (TFR) remains a key salvage option in patients with extensive bone loss. Prior research has demonstrated mixed results of this procedure, and this study aimed to characterize the outcomes of nononcologic TFR in one of the largest single-center modern series.
Methods: A retrospective analysis was conducted on 23 nononcologic TFR procedures performed on 22 patients between 2012 and 2021.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!