Micropipette aspiration of the Pacinian corpuscle.

J Biomech

Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, USA. Electronic address:

Published: October 2017

The Pacinian corpuscle (PC) is a cutaneous mechanoreceptor sensitive to high-frequency vibrations (20-1000Hz). The PC is of importance due to its integral role in somatosensation and the critical need to understand PC function for haptic feedback system development. Previous theoretical and computational studies have modeled the physiological response of the PC to sustained or vibrating mechanical stimuli, but they have used estimates of the receptor's mechanical properties, which remain largely unmeasured. In this study, we used micropipette aspiration (MPA) to determine an apparent Young's modulus for PCs isolated from a cadaveric human hand. MPA was applied in increments of 5mm HO (49Pa), and the change in protrusion length of the PC into the pipette was recorded. The protrusion length vs. suction pressure data were used to calculate the apparent Young's modulus. Using 10 PCs with long-axis lengths of 2.99±0.41mm and short-axis lengths of 1.45±0.22mm, we calculated a Young's modulus of 1.40±0.86kPa. Our measurement is on the same order of magnitude as those approximated in previous models, which estimated the PC to be on the same order of magnitude as skin or isolated cells, so we recommend that a modulus in the kPa range be used in future studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2017.08.005DOI Listing

Publication Analysis

Top Keywords

young's modulus
12
micropipette aspiration
8
pacinian corpuscle
8
apparent young's
8
modulus pcs
8
protrusion length
8
order magnitude
8
aspiration pacinian
4
corpuscle pacinian
4
corpuscle cutaneous
4

Similar Publications

The escalating prevalence of skeletal muscle disorders highlights the critical need for innovative treatments for severe injuries such as volumetric muscle loss. Traditional treatments, such as autologous transplants, are constrained by limited availability and current scaffolds often fail to meet complex clinical needs. This study introduces a new approach to volumetric muscle loss treatment by using a shape-memory polymer (SMP) based on block copolymers of perfluoropolyether and polycaprolactone diol.

View Article and Find Full Text PDF

Titanium alloys are widely used in the manufacture of orthopedic prosthesis given their excellent mechanical properties and biocompatibility. However, the primary drawbacks of traditional titanium alloy prosthesis are their much higher elastic modulus than cancellous bone and poor interfacial adhesion, which lead to poor osseointegration. 3D-printed porous titanium alloys can partly address these issues, but their bio-inertness still requires modifications to adapt to different physiological and pathological microenvironments.

View Article and Find Full Text PDF

Background: Here, we assessed the role of the advanced glycation end-product (AGE) precursor methylglyoxal (MGO) and its non-crosslinking AGE MGO-derived hydroimidazolone (MGH)-1 in aortic stiffening and explored the potential of a glycation stress-lowering compound (Gly-Low) to mitigate these effects.

Methods: Young (3-6 month) C57BL/6 mice were supplemented with MGO (in water) and Gly-Low (in chow). Aortic stiffness was assessed in vivo via pulse wave velocity (PWV) and ex vivo through elastic modulus.

View Article and Find Full Text PDF

In order to solve the problem of drilling deflection, the method of cutting drilling by layers is proposed. The mathematical model of the force of the layered cutting bit was established, and the influencing factors of bit deflection were obtained. The stress equation of the cutting bit is constructed, and the ABAQUS numerical model is established.

View Article and Find Full Text PDF

A combined experimental-computational approach for retinal characterization.

Exp Eye Res

January 2025

Department of Chemistry, Materials and Chemical Engineering "Giulio Natta" (LaBS), Politecnico di Milano, Milano, Italy. Electronic address:

Subretinal injection of gene products is the only treatment option for inherited retinal diseases. However, this procedure induces localized high multiaxial deformations, potentially causing irreversible tissue damage due to retinal overstretching and tearing. Comprehensive characterization of retinal mechanical behavior is essential for performing safe injections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!