A new sample preparation method has been developed for extraction and preconcentration of some heavy metal cations in aqueous samples using cyclohexylamine-based homogeneous liquid-liquid microextraction. In the proposed method, cyclohexylamine was used as both the complexing agent and the extraction solvent. For this purpose, cyclohexylamine at µL level was initially added into an aqueous solution containing Co(II), Ni(II), and Cu(II) ions which was placed in a glass test tube. The mixture was shaken for forming a homogeneous solution. Then sodium chloride was added to the solution. After shaking manually again, the test tube was placed in a water bath thermostated at 70°C. Due to lower solubility of cyclohexylamine at the elevated temperature, a cloudy solution was formed. The fine droplets of cyclohexylamine containing cation-cyclohexylamine complexes were collected on the top of the aqueous phase by centrifuging. The enriched analytes in the upper phase were determined by graphite furnace atomic absorption spectrometry. Several variables possibly affecting the extraction efficiency were investigated and optimized. Under the optimum conditions the calibration curves were linear in the ranges of 80-1000, 40-700, and 80-800ngL for Co, Ni, and Cu, respectively. Repeatability of the proposed method, expressed as relative standard deviation, ranged from 3.3% to 5.2% (n = 6, C = 200ngL). Moreover, the obtained detection limits of the selected analytes were in the range of 15.3-37.7ngL. The accuracy of the developed procedure was verified by analyzing a certified reference material, namely NRCC-SLRS4 Riverine water. Finally, the proposed method was successfully applied for the simultaneous analysis of the selected analytes in environmental water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2017.07.065DOI Listing

Publication Analysis

Top Keywords

proposed method
12
extraction solvent
8
agent extraction
8
extraction preconcentration
8
preconcentration heavy
8
aqueous samples
8
homogeneous liquid-liquid
8
test tube
8
selected analytes
8
cyclohexylamine
5

Similar Publications

An overview of sound source localization based condition monitoring robots.

ISA Trans

December 2024

Centre for Efficiency and Performance Engineering, University of Huddersfield, Huddersfield HD1 3DH, UK. Electronic address:

As artificial intelligence advances and demand for cost-effective equipment maintenance in various fields increases, it is worth insightful research on utilizing robots embedded with sound source localization (SSL) technology for condition monitoring. Combining the two techniques has significant advantages, which are conducive to further classifying and tracking abnormal sources, thereby enhancing system performance at a lower cost. The paper provides an overview of current acoustic-based robotic techniques for condition monitoring, highlights the common SSL methods, and finds that localization performance heavily depends on signal quality.

View Article and Find Full Text PDF

Decoding the rhythmic representation and communication of visual contents.

Trends Neurosci

January 2025

Neural Computation Group, Department of Mathematics and Computer Science, Physics, Geography, Justus-Liebig-Universität Gießen, Gießen 35392, Germany; Center for Mind, Brain and Behavior (CMBB), Philipps-Universität Marburg, Justus-Liebig-Universität Gießen & Technische Universität Darmstadt, Marburg 35032, Germany. Electronic address:

Rhythmic neural activity is considered essential for adaptively modulating responses in the visual system. In this opinion article we posit that visual brain rhythms also serve a key function in the representation and communication of visual contents. Collating a set of recent studies that used multivariate decoding methods on rhythmic brain signals, we highlight such rhythmic content representations in visual perception, imagery, and prediction.

View Article and Find Full Text PDF

Background: Although the method of autocalibration or calibration based on catheter diameters was proposed for fluoroscopic measurement during percutaneous left atrial appendage occlusion (LAAO), it may be imprecise and lead to mismeasurement. We sought to investigate whether the utilization of the surface steel ball calibration (SSBC) method under fluoroscopy could facilitate the fluoroscopic measurement of the post-implanted WATCHMAN device (Boston Scientific Corporation, Natick, MA, USA) in LAAO.

Methods: This retrospective study included 97 consecutive patients who underwent percutaneous LAAO with the WATCHMAN device.

View Article and Find Full Text PDF

Weight loss therapy and addiction: increased risk after bariatric surgery but reduced risk with GLP-1 receptor agonists.

Diabetes Metab

January 2025

Division of Diabetes, Nutrition and Metabolic Disorders, CHU Liège, Liège, Belgium; Division of Clinical Pharmacology, Centre for Interdisciplinary Research on Medicines (CIRM), Liège University, Liège, Belgium. Electronic address:

Background: Obesity is an increasing public health problem because of its high prevalence and associated morbidity and mortality. Two weight-loss strategies are currently used, either bariatric surgery or pharmacological therapy with glucagon-like peptide-1 receptor agonists (GLP-1RAs). Preclinical studies in rodents suggested an increased risk of additive disorders after bariatric surgery contrasting with a reduced risk with GLP-1RAs.

View Article and Find Full Text PDF

Extracellular vesicles in dry eye disease and Sjogren syndrome: A systematic review on their diagnostic and therapeutic role.

Surv Ophthalmol

January 2025

Centre for Ocular Regeneration (CORE), L V Prasad Eye Institute, Hyderabad, Telangana, India; Prof. Krothapalli Ravindranath Ophthalmic Research Biorepository, LV Prasad Eye Institute, Hyderabad, Telangana, India.

Extracellular vesicles (EVs), defined as membrane-bound vesicles released from all cells, are being explored for their diagnostic and therapeutic role in dry eye disease (DED). We systematically shortlisted 32 articles on the role of EVs in diagnosing and treating DED. The systematic review covers the progress in the last 2 decades about the classification and isolation of EVs and their role in DED.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!