Patients with Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) levels 1-2 who either have or are at risk for right ventricular failure face significant morbidity and mortality after continuous flow left ventricular assist device (CF-LVAD) implantation. Currently, the options for biventricular support are limited the Total Artificial Heart (TAH; CardioWest, Syncardia, Tuscon, AZ) or biventricular assist device (BiVAD), which uses bulky extracorporeal or implantable displacement pumps. We describe a successful series based on an innovative approach for biventricular support in consecutive INTERMACS levels 1-2 patients utilizing a HeartWare Ventricular Assist Device (HVAD; HeartWare, Framingham, MA) in a left ventricular (LV-HVAD) and a right atrial (RA-HVAD) configuration. From June 2014 through May 2016, 11 consecutive INTERMACS levels 1-2 patients with evidence of biventricular failure underwent implantation of a CF LVAD (10 LV-HVAD and 1 HeartMate II LVAD, Thoratec, Pleasanton, CA) and RA-HVAD pumps. A total of 4,314 BiVAD support days were accumulated in our case series. Seven patients have undergone orthotopic heart transplant, whereas 3 are ambulatory and are either waiting transplant or reconsideration for transplantation. There is one mortality in this case series, which was due to an intracranial bleed from supratherapeutic anticoagulation. Two other patients experienced hemorrhagic strokes, but without neurologic sequelae, whereas no patients have experienced ischemic strokes. There were two episodes of gastrointestinal bleeding. This is the largest series to date involving this approach with outcomes superior to those previously described in patients receiving biventricular support. We conclude this novel therapy is a viable alternative to current practices in the management of biventricular failure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/MAT.0000000000000645 | DOI Listing |
Cureus
December 2024
Cardiology/Internal Medicine, Luton and Dunstable University Hospital, Luton, GBR.
A thrombus straddling a patent foramen ovale (TSPFO) is a rare condition that presents significant health risks, including stroke or myocardial infarction, and can be life-threatening if not promptly addressed. We report the case of a 42-year-old female with morbid obesity who presented with sudden shortness of breath due to a bilateral pulmonary embolism. Imaging revealed a thrombus extending from the right atrium to the left atrium through the patent foramen ovale (PFO).
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Duke University Medical Center, Durham, North Carolina.
Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.
View Article and Find Full Text PDFNat Med
January 2025
Surgery, University of Maryland School of Medicine, Baltimore, MD, USA.
Following our previous experience with cardiac xenotransplantation of a genetically modified porcine heart into a live human, we sought to achieve improved results by selecting a healthier recipient and through more sensitive donor screening for potential zoonotic pathogens. Here we transplanted a 10-gene-edited pig heart into a 58-year-old man with progressive, debilitating inotrope-dependent heart failure due to ischemic cardiomyopathy who was not a candidate for standard advanced heart failure therapies. He was maintained on a costimulation (anti-CD40L, Tegoprubart) blockade-based immunomodulatory regimen.
View Article and Find Full Text PDFJ Am Coll Cardiol
December 2024
Division of Cardiology, Department of Pediatrics, University of Pennsylvania Perelman School of Medicine, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA.
Background: There are no contemporary reports that highlight the national outcomes for children with congenital heart disease (CHD) undergoing ventricular assist device (VAD) implantation.
Objectives: This study sought to evaluate differences in VAD outcomes for children with CHD to those with non-CHD as well as those with univentricular CHD to those with biventricular CHD.
Methods: Data for CHD and non-CHD patients from the multicenter ACTION (Advanced Cardiac Therapies Improving Outcomes Network) undergoing VAD implantation from April 2018 to February 2023 were included.
Children (Basel)
November 2024
Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy.
Background: Gestational diabetes mellitus (GDM) is the most common complication in pregnancy, representing a serious risk for the mother and fetus. Identifying new biomarkers to ameliorate the screening and improving GDM diagnosis and treatment is crucial. During the last decade, a few studies have used speckle tracking echocardiography (STE) for assessing the myocardial deformation properties of fetuses (FGDM) and infants (IGDM) of GDM women, providing not univocal results.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!