Nowadays, only closed and proprietary integrated operating room systems (IORS) from big manufacturers are available on the market. Hence, the interconnection of components from third-party vendors is only possible with increased time and costs. In the context of the German Federal Ministry of Education and Research (BMBF)-funded project OR.NET (2012-2016), the open integration of medical devices from different manufacturers was addressed. An integrated operating theater based on the open communication standard IEEE 11073 shall give clinical operators the opportunity to choose medical devices independently of the manufacturer. This approach would be advantageous especially for hospital operators and small- and medium-sized enterprises (SME) of medical devices. Actual standards and concepts regarding technical feasibility and the approval process do not cope with the requirements for a modular integration of medical devices in the operating room (OR), based on an open communication standard. Therefore, innovative approval strategies and corresponding certification and test procedures, which cover actual legal and normative standards, have to be developed in order to support the future risk management and the usability engineering process of open integrated medical devices in the OR. The use of standardized device and service profiles and a three-step testing procedure, including conformity, interoperability and integration tests are described in this paper and shall support the manufacturers to integrate their medical devices without disclosing the medical devices' risk analysis and related confidential expertise or proprietary information.

Download full-text PDF

Source
http://dx.doi.org/10.1515/bmt-2017-0055DOI Listing

Publication Analysis

Top Keywords

medical devices
28
communication standard
12
approval process
8
medical
8
integrated medical
8
ieee 11073
8
integrated operating
8
operating room
8
integration medical
8
based open
8

Similar Publications

The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.

View Article and Find Full Text PDF

Background: Despite advancements in prosthetic designs and surgical techniques, patellar dislocation remains a rare but significant complication following total knee arthroplasty, with an incidence ranging between 0.15% and 0.5%.

View Article and Find Full Text PDF

Comparison of AI applications and anesthesiologist's anesthesia method choices.

BMC Anesthesiol

January 2025

Department of Anesthesiology and Reanimation, Mardin Artuklu University School of Medicine, Diyarbakır Road, Artuklu, Mardin, 47100, Turkey.

Background: In medicine, Artificial intelligence has begun to be utilized in nearly every domain, from medical devices to the interpretation of imaging studies. There is still a need for more experience and more studies related to the comprehensive use of AI in medicine. The aim of the present study is to evaluate the ability of AI to make decisions regarding anesthesia methods and to compare the most popular AI programs from this perspective.

View Article and Find Full Text PDF

User satisfaction with Assistive Technology (AT) is one of the crucial factors in the success of any AT service. The current study aimed to estimate satisfaction with AT and the reasons for dissatisfaction and unsuitability among persons with functional difficulties in India. Using the WHO Rapid Assistive Technology Assessment tool, a cross-sectional study was conducted in eight districts, representing four zones of India.

View Article and Find Full Text PDF

Experimental investigation and finite element analysis on the durability of root-filled teeth treated with multisonic irrigation.

Dent Mater

January 2025

Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, USA. Electronic address:

Objective: This study compared the fracture load, stress distribution, and survival probability under cyclic loading of extensively restored teeth treated with multisonic irrigation with those treated with conventional instrumentation, with or without a post.

Methods: Mesial-occlusal-distal cavities were prepared in 30 human mandibular premolars. The teeth were randomly divided into 3 groups of 10 based on the endodontic and restorative procedures: (1) Root canal treatment (RCT) followed by resin composite restoration (control group), (2) RCT followed by a glass fiber post restoration (conventional group), and (3) minimal instrumentation plus multisonic irrigation followed by resin composite restoration (GW group).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!