UK Biobank, a large cohort study, plans to acquire 100,000 cardiac MRI studies by 2020. Although fully-automated left ventricular (LV) analysis was performed in the original acquisition, this was not designed for unsupervised incorporation into epidemiological studies. We sought to evaluate automated LV mass and volume (Siemens syngo InlineVF versions D13A and E11C), against manual analysis in a substantial sub-cohort of UK Biobank participants. Eight readers from two centers, trained to give consistent results, manually analyzed 4874 UK Biobank cases for LV end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and LV mass (LVM). Agreement between manual and InlineVF automated analyses were evaluated using Bland-Altman analysis and the intra-class correlation coefficient (ICC). Tenfold cross-validation was used to establish a linear regression calibration between manual and InlineVF results. InlineVF D13A returned results in 4423 cases, whereas InlineVF E11C returned results in 4775 cases and also reported LVM. Rapid visual assessment of the E11C results found 178 cases (3.7%) with grossly misplaced contours or landmarks. In the remaining 4597 cases, LV function showed good agreement: ESV -6.4 ± 9.0 ml, 0.853 (mean ± SD of the differences, ICC) EDV -3.0 ± 11.6 ml, 0.937; SV 3.4 ± 9.8 ml, 0.855; and EF 3.5 ± 5.1%, 0.586. Although LV mass was consistently overestimated (29.9 ± 17.0 g, 0.534) due to larger epicardial contours on all slices, linear regression could be used to correct the bias and improve accuracy. Automated InlineVF results can be used for case-control studies in UK Biobank, provided visual quality control and linear bias correction are performed. Improvements between InlineVF D13A and InlineVF E11C show the field is rapidly advancing, with further improvements expected in the near future.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5809564PMC
http://dx.doi.org/10.1007/s10554-017-1225-9DOI Listing

Publication Analysis

Top Keywords

fully-automated left
8
left ventricular
8
mass volume
8
inlinevf
8
manual inlinevf
8
linear regression
8
inlinevf d13a
8
inlinevf e11c
8
volume
5
biobank
5

Similar Publications

Predicting mortality after transcatheter aortic valve replacement using AI-based fully automated left atrioventricular coupling index.

J Cardiovasc Comput Tomogr

January 2025

Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA; Department of Diagnostic and Interventional Radiology, University Medical Center of Johannes Gutenberg-University, Mainz, Germany; German Centre for Cardiovascular Research, Mainz, Germany.

Background: This study aimed to determine whether artificial intelligence (AI)-based automated assessment of left atrioventricular coupling index (LACI) can provide incremental value above other traditional risk factors for predicting mortality among patients with severe aortic stenosis (AS) undergoing coronary CT angiography (CCTA) before transcatheter aortic valve replacement (TAVR).

Methods: This retrospective study evaluated patients with severe AS who underwent CCTA examination before TAVR between September 2014 and December 2020. An AI-prototype software fully automatically calculated left atrial and left ventricular end-diastolic volumes and LACI was defined by the ratio between them.

View Article and Find Full Text PDF

Fully Automated Assessment of Cardiac Chamber Volumes and Myocardial Mass on Non-Contrast Chest CT with a Deep Learning Model: Validation Against Cardiac MR.

Diagnostics (Basel)

December 2024

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg im Breisgau, Germany.

: To validate the automated quantification of cardiac chamber volumes and myocardial mass on non-contrast chest CT using cardiac MR (CMR) as a reference. : We retrospectively included 53 consecutive patients who received non-contrast chest CT and CMR within three weeks. A deep learning model created cardiac segmentations on axial soft-tissue reconstructions from CT, covering all four cardiac chambers and the left ventricular myocardium.

View Article and Find Full Text PDF

Transthoracic Echocardiography (TTE) is a crucial tool for assessing cardiac morphology and function quickly and non-invasively without ionising radiation. However, the examination is subject to intra- and inter-user variability and recordings are often limited to 2D imaging and assessments of end-diastolic and end-systolic volumes. We have developed a novel, fully automated machine learning-based framework to generate a personalised 4D (3D plus time) model of the left ventricular (LV) blood pool with high temporal resolution.

View Article and Find Full Text PDF

The role of artificial intelligence in standardizing global longitudinal strain measurements in echocardiography.

Eur Heart J Imaging Methods Pract

October 2024

Department for Internal Medicine and Cardiology, Herzzentrum Dresden, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Fetscherstr. 76, 01307 Dresden, Germany.

Aims: To evaluate the accuracy and feasibility of artificial intelligence (AI) in left ventricular global longitudinal strain (GLS) analysis as compared to conventional (Manual) and semi-automated (SemiAuto) method in echocardiography (Echo).

Methods And Results: GLS validation was performed on 550 standard Echo exams by expert cardiologists. The performance of a beginner cardiologist without experience of GLS analysis was assessed on a subset of 90 exams.

View Article and Find Full Text PDF

Background And Purpose: Dual energy computed tomography (DECT) is an advanced CT technique which has been shown to improve accuracy in distinguishing between intracranial hemorrhage and calcification, which is often challenging on conventional CT and therefore may warrant repeat imaging in the emergency department (ED) to document stability and exclude enlarging intracranial hemorrhage. We hypothesized that implementation of a DECT head protocol with fully automated post processing in the ED would decrease the need for repeat imaging and therefore reduce overall ED length of stay (LOS).

Materials And Methods: This is a retrospective study comparing ED length of stay over a one-year period before (7/1/2016-6/30/2017) and after (7/1/2018-6/30/2019) implementing a DECT head protocol, for patients scanned for headache, trauma or fall, who were found to have indeterminate intracranial hyperdensities on conventional images, and were subsequently discharged home from the ER (excluding patients who were admitted, taken to the OR, or left against medical advice).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!