Purpose: The study is to compare the Modified Physical Performance Test (MPPT) and Short Physical Performance Battery (SPPB) as metrics of mobility and function in older men with peripheral arterial disease (PAD).
Materials And Methods: A total of 51 men (55-87 years) with PAD underwent functional testing including the SPPB, MPPT, Walking Impairment Questionnaire (WIQ), stair ascent, and 6-min walk distance. Individuals were grouped according to SPPB and MPPT scores as not limited on either, limited only on the MPPT, or limited on both.
Results: The MPPT identified a higher proportion of patients as being functionally limited than the SPPB (p < 0.001). Men identified as limited only by the MPPT, and not the SPPB, were subsequently confirmed to have lower function on all measures compared to those not identified as limited by either the SPPB or the MPPT (p < 0.02).
Conclusions: These findings suggest the MPPT is an appropriate measure to identify early declines in men with PAD and may identify global disability better than SPPB. Implications for rehabilitation Individuals with peripheral arterial disease have low activity levels and are at risk for a loss of independence and global disability. Early detection of decline in mobility and global function would allow for interventions before large changes in ambulatory ability or a loss of functional independence occur. This study shows the Modified Physical Performance Test may be an appropriate test to identify early decline in function in men with peripheral arterial disease.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5904015 | PMC |
http://dx.doi.org/10.1080/09638288.2017.1367966 | DOI Listing |
Pediatr Radiol
January 2025
Department of Radiology, College of Medicine, University of Florida, PO Box 100374, Gainesville, FL, 32610-0374, USA.
Purpose: To evaluate whether adult and pediatric trauma center status, as well as the presence of dedicated child protection teams, influences radiology resident performance in detecting non-accidental trauma on the Emergent/Critical Care Imaging Simulation (WIDI SIM) exam.
Materials And Methods: We retrospectively analyzed 639 WIDI SIM exam scores for four pediatric non-accidental trauma cases completed by radiology residents across 33 programs. Residents were stratified by level (R1-R4) and institutional factors, including adult trauma center status, pediatric trauma center status, and child protection team presence.
Cardiol Rev
January 2025
Ghulam Muhammad Mahar Medical College, Sukkur, Pakistan.
Obstructive sleep apnea (OSA), a highly prevalent and serious disorder with significant complications, causes considerable daytime and nighttime symptoms as well as long-term consequences and is yet an underdiagnosed and inadequately treated condition. Patients with OSA undergo frequent awakenings during the sleep cycle and find it impossible to get restorative sleep. Individuals are extremely fatigued, sleepy, and irritable throughout the day.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99354, United States.
As the energy density of lithium-ion batteries (LIBs) increases, the shortened cycle life and the increased safety hazards of LIBs are drawing increasing concerns. To address such challenges, a series of localized high-concentration electrolytes (LHCEs) based on a solvating-solvent mixture of tetramethylene sulfone and trimethyl phosphate and a high flash-point diluent 1H,1H,5H-octafluoropentyl 1,1,2,2-tetrafluoroethyl ether were designed. The LHCEs exhibited nonflammability and greatly suppressed heat release at elevated temperatures, which would potentially improve the safety performance of the LIBs.
View Article and Find Full Text PDFJ Am Chem Soc
January 2025
State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Materials, Xiamen University, Xiamen 361005, China.
Advancements in the development of fast-charging and long-lasting microstructured alloying anodes with high volumetric capacities are essential for enhancing the operational efficiency of sodium-ion batteries (SIBs). These anodes, however, face challenges such as declined cyclability and rate capability, primarily due to mechanical degradation reduced by significant volumetric changes (over 252%) and slow kinetics of sodium-ion storage. Herein, we introduce a novel anode design featuring densely packed bismuth (Bi) embedded within highly conductive carbon microspheres to overcome the aforementioned challenges.
View Article and Find Full Text PDFJ Am Chem Soc
January 2025
New Chemistry Unit, International Centre for Materials Science and School of Advanced Materials, Jawaharlal Nehru Centre for Advanced Scientific Research (JNCASR), Bangalore, Jakkur P.O. 560064, India.
Seeking new and efficient thermoelectric materials requires a detailed comprehension of chemical bonding and structure in solids at microscopic levels, which dictates their intriguing physical and chemical properties. Herein, we investigate the influence of local structural distortion on the thermoelectric properties of TlCuS, a layered metal sulfide featuring edge-shared Cu-S tetrahedra within CuS layers. While powder X-ray diffraction suggests average crystallographic symmetry with no distortion in CuS tetrahedra, the synchrotron X-ray pair distribution function experiment exposes concealed local symmetry breaking, with dynamic off-centering distortions of the CuS tetrahedra.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!