Background: Reducing positive margin rate (PMR) and reoperation rate in breast-conserving operations remains a challenge, mainly regarding ductal carcinoma in situ (DCIS). Intra-operative margin assessment tools have emerged to reduce PMR over the last decades, including specimen radiography (SR). No consensus has been reached on the reliability and efficacy of SR in DCIS.

Objective: We performed a systematic literature review to assess the performance characteristics of SR for margin assessment of breast lesions with pure DCIS and invasive cancers with DCIS components.

Methods: A literature search was conducted for diagnostic studies up to April 2017 concerning SR for intra-operative margin assessment of breast lesions with pure DCIS or with DCIS components. Studies reporting sensitivity and specificity calculated using final pathology report as reference test were included. Due to improved imaging technology, studies published more than 15 years ago were excluded. Methodological quality was assessed using quality assessment of diagnostic accuracy studies-2 checklist. Due to clinical and methodological diversity, meta-analysis was considered not useful.

Results: Of 235 citations identified, 9 met predefined inclusion criteria and documented diagnostic efficacy data. Sensitivity ranged from 22 to 77% and specificity ranged from 51 to 100%. Positive predictive value and negative predictive value ranged from 53 to 100% and 32 to 95%, respectively. High or unclear risk of bias was found in reference standard in 5 of 9 studies. High concerns regarding applicability of index test were found in 6 of 9 studies.

Conclusions: The present results do not support the routine use of intra-operative specimen radiography to reduce the rate of positive margins in patients undergoing breast-conserving surgery for pure DCIS or the DCIS component in invasive cancer. Future studies need to differentiate between initial and final specimen margin involvement. This could provide surgeons with a number needed to treat for a more applicable outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10549-017-4475-2DOI Listing

Publication Analysis

Top Keywords

margin assessment
16
specimen radiography
12
pure dcis
12
performance characteristics
8
ductal carcinoma
8
carcinoma situ
8
intra-operative margin
8
assessment breast
8
breast lesions
8
lesions pure
8

Similar Publications

Objectives: In advanced stages of osteoradionecrosis, medication-related osteonecrosis of the jaw, and osteomyelitis, a resection of sections of the mandible may be unavoidable. The determination of adequate bony resection margins is a fundamental problem because bony resection margins cannot be secured intraoperatively. Single-photon emission computed tomography (SPECT-CT) is more accurate than conventional imaging techniques in detecting inflammatory jaw pathologies.

View Article and Find Full Text PDF

Objectives: To develop and validate a lesion-based grading system using clinicopathological and MRI features for predicting positive surgical margin (PSM) following robotic-assisted laparoscopic prostatectomy (RALP) among prostate cancer (PCa) patients.

Methods: Consecutive MRI examinations of patients undergoing RALP for PCa were retrospectively collected from two medical institutions. Patients from center 1 undergoing RALP between January 2020 and December 2021 were included in the derivation cohort and those between January 2022 and December 2022 were allocated to the validation cohort.

View Article and Find Full Text PDF

Background: Surgery remains the cornerstone of treatment for rhabdomyosarcoma (RMS) in children. However, there is considerable variation in surgical management practices worldwide, highlighting the need for standardized Clinical Practice Guidelines (CPG).

Methods: The CPG development involved assembling a multidisciplinary group, prioritizing 10 key topic areas, conducting evidence searches, and synthesizing findings.

View Article and Find Full Text PDF

Purpose: This study evaluates the feasibility of utilizing robotic-assisted bronchoscopy with cone beam computed tomography (RB-CBCT) platform to perform low-dose-rate brachytherapy implants (LDR-BT) in a mechanically ventilated human cadaveric model. Post-implant dosimetry was compared to standard stereotactic body radiation therapy plans (SBRT).

Materials And Methods: The RB-CBCT platform was used to place inert LDR-BT seeds into mechanically ventilated human cadavers with percutaneously injected pseudotumors.

View Article and Find Full Text PDF

Rationale: The biodegradable polymer BioMatrix Alpha™ stent contains biolimus A9 drug which is sirolimus derivative increase in lipophicity. The biodegradable polymer sirolimus eluting Combo™ stent is a dual-therapy sirolimus-eluting and CD34+ antobody coated stent capturing endothelial progenitor cells (EPCs).

Hypothesis: The main hypothesis of the SORT OUT XI trial was that the biodegradable polymer biolimus A9 BioMatrix Alpha ™ stent is noninferior to the biodegradable polymer sirolimus eluting Combo™ stent in an all-comers population with coronary artery disease undergoing percutaneous coronary intervention (PCI).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!