Objectives: To report the safety and clinical outcomes of placing current magnetic resonance imaging (MRI) components inside and outside the MRI bore during MRIs.
Design: Retrospective case series.
Setting: Four trauma centers (3 Level I and 1 Level II), from January 2005 to January 2015.
Patients: All patients who had MRIs with external fixators in place either inside or outside the MRI bore.
Intervention: MRI of patients with external fixator in place.
Main Outcome Measurements: Adverse events were defined as catastrophic pullout of the external fixator during the MRI, thermal injury to the skin, severe field distortions precluding the intended imaging, alterations of the magnetic field, or visible structural damage to the magnet casing.
Results: Thirty-eight patients with 44 external fixators were identified who had MRI with the fixator inside or outside the MRI bore. Twelve patients with 13 external fixators had MRI with the external fixator inside the MRI bore. Twenty-seven patients with 32 external fixators had MRI with the external fixator outside the MRI bore. There were no adverse events.
Conclusions: Although no universal guidelines exist, there are circumstances in which obtaining MRIs of patients with external fixators can be safe. This is the first clinical series with the primary outcome of safety when placing modern external components both inside and outside an MRI bore during a scan.
Level Of Evidence: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0000000000000954 | DOI Listing |
Nanomaterials (Basel)
December 2024
Laboratory of Applied Electrochemistry, Dipartimento di Chimica, Università degli Studi di Milano, Via Golgi, 19, 20133 Milan, Italy.
Magnetic resonance imaging (MRI) is a technique that employs strong magnetic fields and radio frequencies to generate detailed images of the body's interior. In oncology patients, gadolinium-based contrast agents (GBCAs) are frequently administered to enhance the visualization of tumors. Those contrast agents are gadolinium chelates, characterized by high stability that prevents the release of the toxic gadolinium ion into the body.
View Article and Find Full Text PDFJ Biomed Phys Eng
December 2024
Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Background: T thermometry is considered a straight method for the safety monitoring of patients with deep brain stimulation (DBS) electrodes against radiofrequency-induced heating during Magnetic Resonance Imaging (MRI), requiring different sequences and methods.
Objective: This study aimed to compare two T thermometry methods and two low specific absorption rate (SAR) imaging sequences in terms of the output image quality.
Material And Methods: In this experimental study, a gel phantom was prepared, resembling the brain tissue properties with a copper wire inside.
Algorithms
December 2023
Fetal-Neonatal Neuroimaging and Developmental Science Center, Division of Newborn Medicine, Department of Medicine, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
In drug-resistant epilepsy, a visual inspection of intracranial electroencephalography (iEEG) signals is often needed to localize the epileptogenic zone (EZ) and guide neurosurgery. The visual assessment of iEEG time-frequency (TF) images is an alternative to signal inspection, but subtle variations may escape the human eye. Here, we propose a deep learning-based metric of visual complexity to interpret TF images extracted from iEEG data and aim to assess its ability to identify the EZ in the brain.
View Article and Find Full Text PDFNMR Biomed
February 2025
CIBM Center for Biomedical Imaging, Lausanne, Switzerland.
Magnetic resonance spectroscopic imaging (MRSI) enables the simultaneous noninvasive acquisition of MR spectra from multiple spatial locations inside the brain. Although H-MRSI is increasingly used in the human brain, it is not yet widely applied in the preclinical setting, mostly because of difficulties specifically related to very small nominal voxel size in the rat brain and low concentration of brain metabolites, resulting in low signal-to-noise ratio (SNR). In this context, we implemented a free induction decay H-MRSI sequence (H-FID-MRSI) in the rat brain at 14.
View Article and Find Full Text PDFPersonal Disord
December 2024
School of Psychology, University of Wollongong.
Individuals with borderline personality disorder (BPD) often hold pervasive and negative self-views and experience feelings of low connectedness toward others despite effective treatment. This study aimed to identify neural and affective mechanisms of identity disturbance in BPD that contribute to difficulties in relating to others. Participants diagnosed with BPD ( = 34) and nonclinical controls (NCC; = 35) completed a within-subject social feedback task inside a magnetic resonance imaging scanner.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!