Stainless steel alloys containing 8% to 12% nickel and 17% to 22% chromium are generally used in orthodontic appliances. A major concern has been the performance of alloys in the environment in which they are intended to function in the oral cavity. Biodegradation and metal release increase the risk of hypersensitivity and cytotoxicity. This case report describes for the first time a CAD/CAM zirconium bar as a bonded mandibular fixed retainer with 2-year follow-up in a patient who is subjected to long-term treatment with fixed orthodontic appliance and suspected to have metal hypersensitivity as shown by the considerable increase of nickel and chromium concentrations in a sample of patient's unstimulated saliva. The CAD/CAM design included a 1.8 mm thickness bar on the lingual surface of lower teeth from canine to canine with occlusal rests on mesial side of first premolars. For better retention, a thin layer of feldspathic ceramic was added to the inner surface of the bar and cemented with two dual-cured cement types. The patient's complaint subsided 6 weeks after cementation. Clinical evaluation appeared to give good functional value where the marginal fit of digitized CAD/CAM design and glazed surface offered an enhanced approach of fixed retention.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5551476 | PMC |
http://dx.doi.org/10.1155/2017/1583403 | DOI Listing |
BMC Oral Health
January 2025
Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
Background: Conservative dentistry introduced modern restoration designs, contributing to the greater use of partial-coverage ceramic restorations. New strong bondable ceramic materials made fabricating partial coverage ceramic restorations easier to restore the badly destructed teeth.
Aim Of The Study: This study investigated the impact of three distinct overlay preparation designs on the marginal fit (both before and after thermal aging) and the fracture resistance of overlay restorations fabricated using advanced zirconia-reinforced lithium disilicate (ALD) CAD/CAM glass-ceramic blocks.
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics, Chhattisgarh Dental College and Hospital, Rajnandgaon, Chhattishgarh, India.
Aim: The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.
Settings And Design: The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.
Materials And Methods: Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone.
BMC Oral Health
January 2025
Department of Basic Medical Science, Faculty of Medicine, Yozgat Bozok University, Yozgat, 66100, Türkiye, Turkey.
Background: Although surface finishing processes are effective against Streptococcus mutans biofilm, the mechanism of action of saliva with different acidity values has not been studied in detail. This study aims to produce four different all-ceramic materials in a single session with CAD/CAM devices and apply two different surface finishing processes, glazing and polishing, and then determine the retention of Streptococcus mutants on the surfaces of the materials in saliva with varying levels of acidity.
Methods: Zirconia-reinforced lithium silicate (Vita Suprinity, Vita Zahnfabrik, Bad Saöckingen, Germany), monochromatic feldspar (Vitablocs Mark 2, Vita Zahnfabrik, Bad Saöckingen, Germany), leucite glass ceramic (IPS Empress CAD, Ivoclar Vivadent, Liechtenstein), and monolithic zirconia (Incoris TZI (Cerec) Sirona, Germany) were used in the study.
BMC Oral Health
December 2024
Faculty of Odonto-Stomatology, University of Health Sciences, Vietnam National University Ho Chi Minh City, Ho Chi Minh City, Vietnam.
Background: The success of a restoration largely depends on the quality of its fit. This study aimed to investigate the fit quality of monolithic zirconia veneers (MZVs) produced through traditional and digital workflows.
Methods: A typodont maxillary right central incisor was prepared.
BMC Oral Health
December 2024
Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Dakahlia Governorate, Egypt.
Background: The objective of this study was to investigate the effect of bonded substrate, zirconia surface conditioning and the interaction between them on the shear bond strength of monolithic zirconia.
Methods: Forty-eight monolithic zirconia discs were CAD-CAM fabricated and divided into two groups according to surface treatment either as milled and universal primer application (Monobond N, Ivoclar-Vivadent) (P) or sandblasting then universal primer application (Monobond N) (SP). Each main group was further divided into three test groups according to the bonded substrate: dentin (DSP, DP), composite (CSP, CP) or resin modified glass ionomer (RMGI) (GSP, GP).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!